T2-Weighted Dixon Turbo Spin Echo for Accelerated Simultaneous Grading of Whole-Body Skeletal Muscle Fat Infiltration and Edema in Patients With Neuromuscular Diseases. Issue 4 (July 2018)
- Record Type:
- Journal Article
- Title:
- T2-Weighted Dixon Turbo Spin Echo for Accelerated Simultaneous Grading of Whole-Body Skeletal Muscle Fat Infiltration and Edema in Patients With Neuromuscular Diseases. Issue 4 (July 2018)
- Main Title:
- T2-Weighted Dixon Turbo Spin Echo for Accelerated Simultaneous Grading of Whole-Body Skeletal Muscle Fat Infiltration and Edema in Patients With Neuromuscular Diseases
- Authors:
- Schlaeger, Sarah
Klupp, Elisabeth
Weidlich, Dominik
Cervantes, Barbara
Foreman, Sarah C.
Deschauer, Marcus
Schoser, Benedikt
Katemann, Christoph
Kooijman, Hendrik
Rummeny, Ernst J.
Zimmer, Claus
Kirschke, Jan S.
Karampinos, Dimitrios C. - Abstract:
- Abstract : Objective: The assessment of fatty infiltration and edema in the musculature of patients with neuromuscular diseases (NMDs) typically requires the separate performance of T1 -weighted and fat-suppressed T2 -weighted sequences. T2 -weighted Dixon turbo spin echo (TSE) enables the generation of T2 -weighted fat- and water-separated images, which can be used to assess both pathologies simultaneously. The present study examines the diagnostic performance of T2 -weighted Dixon TSE compared with the standard sequences in 10 patients with NMDs and 10 healthy subjects. Methods: Whole-body magnetic resonance imaging was performed including T1 -weighted Dixon fast field echo, T2 -weighted short-tau inversion recovery, and T2 -weighted Dixon TSE. Fatty infiltration and intramuscular edema were rated by 2 radiologists using visual semiquantitative rating scales. To assess intermethod and interrater agreement, weighted Cohen's κ coefficients were calculated. Results: The ratings of fatty infiltration showed high intermethod and high interrater agreement (T1 -weighted Dixon fast field echo vs T2 -weighted Dixon TSE fat image). The evaluation of edematous changes showed high intermethod and good interrater agreement (T2 -weighted short-tau inversion recovery vs T2 -weighted Dixon TSE water image). Conclusions: T2 -weighted Dixon TSE imaging is an alternative for accelerated simultaneous grading of whole-body skeletal muscle fat infiltration and edema in patients with NMDs.
- Is Part Of:
- Journal of computer assisted tomography. Volume 42:Issue 4(2018)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 42:Issue 4(2018)
- Issue Display:
- Volume 42, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2018-0042-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-07
- Subjects:
- skeletal muscle -- fat infiltration -- edema -- neuromuscular diseases -- Dixon MRI
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000723 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10511.xml