Motion Artifact Reduction From High-Pitch Dual-Source Computed Tomography Pulmonary Angiography. Issue 4 (July 2018)
- Record Type:
- Journal Article
- Title:
- Motion Artifact Reduction From High-Pitch Dual-Source Computed Tomography Pulmonary Angiography. Issue 4 (July 2018)
- Main Title:
- Motion Artifact Reduction From High-Pitch Dual-Source Computed Tomography Pulmonary Angiography
- Authors:
- Bunch, Paul M.
Fulwadhva, Urvi P.
Wortman, Jeremy R.
Primak, Andrew N.
Madan, Rachna
Steigner, Michael L.
Sodickson, Aaron D. - Abstract:
- Abstract : Purpose: The purpose of this study was to compare quantitative and qualitative measures of aortic, cardiac, and respiratory motion artifact between high-pitch dual-source (DS) and single-source (SS) computed tomography pulmonary angiography (CTPA) protocols. Methods: This institutional review board–approved, Health Insurance Portability and Accountability Act–compliant study retrospectively reviewed 80 non–electrocardiogram-gated CTPA examinations acquired with a second-generation DS system at 100 kVp following 50 mL iodinated contrast injection — 40 consecutive SS and 40 consecutive DS studies. Quantitative measures of aortic, left ventricular, and diaphragmatic motion were recorded as the maximal excursion of a structure's "double image, " and 3 independent readers performed qualitative motion assessments. Pulmonary arterial contrast enhancement, image noise, and radiation dose metrics were recorded. Statistical analyses were performed with 1-way analysis of variance and Fisher exact test. Results: Dual source outperformed SS technique in both quantitative and qualitative measures of motion. Mean distances between motion-artifact double images were reduced with DS protocol at each location (all P ⩽ 0.004), and DS examinations were more likely to receive an assessment of no motion in all locations (all P < 0.0001). The DS protocol demonstrated increases in contrast enhancement, although increased image noise resulted in lower enhancement to noise ratio. MeanAbstract : Purpose: The purpose of this study was to compare quantitative and qualitative measures of aortic, cardiac, and respiratory motion artifact between high-pitch dual-source (DS) and single-source (SS) computed tomography pulmonary angiography (CTPA) protocols. Methods: This institutional review board–approved, Health Insurance Portability and Accountability Act–compliant study retrospectively reviewed 80 non–electrocardiogram-gated CTPA examinations acquired with a second-generation DS system at 100 kVp following 50 mL iodinated contrast injection — 40 consecutive SS and 40 consecutive DS studies. Quantitative measures of aortic, left ventricular, and diaphragmatic motion were recorded as the maximal excursion of a structure's "double image, " and 3 independent readers performed qualitative motion assessments. Pulmonary arterial contrast enhancement, image noise, and radiation dose metrics were recorded. Statistical analyses were performed with 1-way analysis of variance and Fisher exact test. Results: Dual source outperformed SS technique in both quantitative and qualitative measures of motion. Mean distances between motion-artifact double images were reduced with DS protocol at each location (all P ⩽ 0.004), and DS examinations were more likely to receive an assessment of no motion in all locations (all P < 0.0001). The DS protocol demonstrated increases in contrast enhancement, although increased image noise resulted in lower enhancement to noise ratio. Mean radiation dose was 60% lower using the DS protocol. Conclusion: High-pitch DS CTPA significantly reduces artifacts resulting from ascending aortic, cardiac, and diaphragmatic motion. … (more)
- Is Part Of:
- Journal of computer assisted tomography. Volume 42:Issue 4(2018)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 42:Issue 4(2018)
- Issue Display:
- Volume 42, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2018-0042-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-07
- Subjects:
- CT pulmonary angiography -- motion artifact -- high-pitch -- dual-source -- CT protocols
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000736 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10511.xml