4-Meter Gait Speed Test in Chronic Obstructive Pulmonary Disease: INTERRATER RELIABILITY USING A STOPWATCH. Issue 4 (July 2018)
- Record Type:
- Journal Article
- Title:
- 4-Meter Gait Speed Test in Chronic Obstructive Pulmonary Disease: INTERRATER RELIABILITY USING A STOPWATCH. Issue 4 (July 2018)
- Main Title:
- 4-Meter Gait Speed Test in Chronic Obstructive Pulmonary Disease
- Authors:
- Bisca, Gianna Waldrich
Fava, Lucas Rodrigues
Morita, Andrea Akemi
Machado, Felipe Vilaça Cavallari
Pitta, Fabio
Hernandes, Nidia Aparecida - Abstract:
- Abstract : Purpose: 4-meter gait speed (4MGS) is increasingly used to assess functional performance in patients with chronic obstructive pulmonary disease. However, the current literature lacks information regarding some technical standards for this test. Therefore, the purpose of this study was to compare and to evaluate the interrater reliability between a stopwatch and video recording used as timing systems for the 4MGS in patients with chronic obstructive pulmonary disease, as well as to verify the interrater reliability between 2 observers measuring the 4MGS time using a manual stopwatch. Methods: Fifty-one patients performed the 4MGS using 4 different protocols (random order): walking at the usual and maximum speed in a 4-meter course and walking at the same 2 speeds on an 8-m course using a 2-m acceleration zone, a 4-meter timing area, and a 2-m deceleration zone. Gait speed was measured simultaneously using a stopwatch and a video recording. In a subanalysis (n = 24), 2 independent observers timed the 4MGS using a stopwatch. Results: There was no significant difference in comparison between the 2 timing methods ( P > .05 for all), and the reliability between video recording and stopwatch was excellent in all 4MGS studied protocols (intraclass correlation coefficient ≥ 0.91). Moreover, when comparing gait speed measured by 2 observers using a stopwatch, no significant difference was found among all proposed protocols ( P > .05 for all), and there was also excellentAbstract : Purpose: 4-meter gait speed (4MGS) is increasingly used to assess functional performance in patients with chronic obstructive pulmonary disease. However, the current literature lacks information regarding some technical standards for this test. Therefore, the purpose of this study was to compare and to evaluate the interrater reliability between a stopwatch and video recording used as timing systems for the 4MGS in patients with chronic obstructive pulmonary disease, as well as to verify the interrater reliability between 2 observers measuring the 4MGS time using a manual stopwatch. Methods: Fifty-one patients performed the 4MGS using 4 different protocols (random order): walking at the usual and maximum speed in a 4-meter course and walking at the same 2 speeds on an 8-m course using a 2-m acceleration zone, a 4-meter timing area, and a 2-m deceleration zone. Gait speed was measured simultaneously using a stopwatch and a video recording. In a subanalysis (n = 24), 2 independent observers timed the 4MGS using a stopwatch. Results: There was no significant difference in comparison between the 2 timing methods ( P > .05 for all), and the reliability between video recording and stopwatch was excellent in all 4MGS studied protocols (intraclass correlation coefficient ≥ 0.91). Moreover, when comparing gait speed measured by 2 observers using a stopwatch, no significant difference was found among all proposed protocols ( P > .05 for all), and there was also excellent reliability between the 2 independent observers (intraclass correlation coefficient ≥ 0.94). Conclusion: The stopwatch, a low-cost and feasible tool, is reliable as a timing device for the 4MGS in patients with chronic obstructive pulmonary disease. Abstract : The stopwatch, a low-cost and feasible tool, is a reliable timing device for different protocols of the 4-meter gait speed test in patients with chronic obstructive pulmonary disease. There were no significant differences comparing gait speed assessed by video recording and gait speed measured by 2 observers using a stopwatch. … (more)
- Is Part Of:
- Journal of cardiopulmonary rehabilitation and prevention. Volume 38:Issue 4(2018)
- Journal:
- Journal of cardiopulmonary rehabilitation and prevention
- Issue:
- Volume 38:Issue 4(2018)
- Issue Display:
- Volume 38, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 38
- Issue:
- 4
- Issue Sort Value:
- 2018-0038-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-07
- Subjects:
- activities of daily living -- chronic obstructive pulmonary disease -- exercise assessment -- interrater reliability
Cardiopulmonary system -- Diseases -- Patients -- Rehabilitation -- Periodicals
Cardiopulmonary system -- Diseases -- Prevention -- Periodicals
616.103 - Journal URLs:
- http://www.jcrjournal.com ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01273116-000000000-00000 ↗
http://journals.lww.com/cptj/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/HCR.0000000000000297 ↗
- Languages:
- English
- ISSNs:
- 1932-7501
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.864550
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10526.xml