A case study on implantation strategies to mitigate coronary obstruction in a patient receiving transcatheter aortic valve replacement. (24th May 2019)
- Record Type:
- Journal Article
- Title:
- A case study on implantation strategies to mitigate coronary obstruction in a patient receiving transcatheter aortic valve replacement. (24th May 2019)
- Main Title:
- A case study on implantation strategies to mitigate coronary obstruction in a patient receiving transcatheter aortic valve replacement
- Authors:
- Hatoum, Hoda
Lilly, Scott M.
Crestanello, Juan
Dasi, Lakshmi Prasad - Abstract:
- Abstract: Coronary obstruction is a life threatening complication during and post-transcatheter aortic valve replacement (TAVR). The objective of this preliminary work is to investigate the mechanisms underlying coronary obstruction in a patient after TAVR, in whom coronary obstruction was confirmed in addition to highlighting the importance of pre-procedural planning. The aortic root of an 80-year old male patient with coronary obstruction during TAVR–where a 29 mm SAPIEN 3 was deployed-was segmented from Computed Tomography scans and 3D-printed with compliant material. Flow and pressure data were acquired in this 3D-printed model in-vitro using a pulse duplicator under physiological conditions for the cases: a 29 mm SAPIEN 3, a 26 mm SAPIEN 3 expanded with a 29 mm balloon, and a 31 mm Medtronic-CoreValve deployed annularly, supra and sub-annularly respectively. Only the CoreValve in sub-annular axial position and the 29 mm SAPIEN 3 yielded pressure gradients (PG) lower than 10 mmHg (6.76 ± 0.52 and 5.72 ± 0.13 mmHg respectively) while the 26 mm SAPIEN 3, CoreValve in normal and supra-annular positions yielded higher PGs (15.5 ± 0.48, 12.2 ± 0.15 and 10.8 ± 0.24 mmHg respectively). 29 mm SAPIEN 3 implantation yielded an FFR value of 45.7 ± 0.6%. However, 31 mm CoreValve in any of the three different annular positions yielded FFR values going from 89.6 ± 1.1% in supra-annular position to 98.3 ± 1.1% in sub-annular position. Implantation with a 26 mm SAPIEN 3 expanded with aAbstract: Coronary obstruction is a life threatening complication during and post-transcatheter aortic valve replacement (TAVR). The objective of this preliminary work is to investigate the mechanisms underlying coronary obstruction in a patient after TAVR, in whom coronary obstruction was confirmed in addition to highlighting the importance of pre-procedural planning. The aortic root of an 80-year old male patient with coronary obstruction during TAVR–where a 29 mm SAPIEN 3 was deployed-was segmented from Computed Tomography scans and 3D-printed with compliant material. Flow and pressure data were acquired in this 3D-printed model in-vitro using a pulse duplicator under physiological conditions for the cases: a 29 mm SAPIEN 3, a 26 mm SAPIEN 3 expanded with a 29 mm balloon, and a 31 mm Medtronic-CoreValve deployed annularly, supra and sub-annularly respectively. Only the CoreValve in sub-annular axial position and the 29 mm SAPIEN 3 yielded pressure gradients (PG) lower than 10 mmHg (6.76 ± 0.52 and 5.72 ± 0.13 mmHg respectively) while the 26 mm SAPIEN 3, CoreValve in normal and supra-annular positions yielded higher PGs (15.5 ± 0.48, 12.2 ± 0.15 and 10.8 ± 0.24 mmHg respectively). 29 mm SAPIEN 3 implantation yielded an FFR value of 45.7 ± 0.6%. However, 31 mm CoreValve in any of the three different annular positions yielded FFR values going from 89.6 ± 1.1% in supra-annular position to 98.3 ± 1.1% in sub-annular position. Implantation with a 26 mm SAPIEN 3 expanded with a 29 mm balloon also yielded an FFR of 92.1 ± 1.2%. Coronary obstruction in this patient could have been prevented through usage of different valve types and/or through usage of a different combination of valve size-balloon sizes. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 89(2019)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 89(2019)
- Issue Display:
- Volume 89, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 89
- Issue:
- 2019
- Issue Sort Value:
- 2019-0089-2019-0000
- Page Start:
- 115
- Page End:
- 118
- Publication Date:
- 2019-05-24
- Subjects:
- Transcatheter aortic valve replacement -- TAVR -- Coronary obstruction -- Fractional flow reserve -- FFR
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2019.04.010 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10520.xml