Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance. Issue 1 (December 2016)
- Main Title:
- Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance
- Authors:
- D'Errico, Luigia
Lamacie, Mariana
Jimenez Juan, Laura
Deva, Djeven
Wald, Rachel
Ley, Sebastian
Hanneman, Kate
Thavendiranathan, Paaladinesh
Wintersperger, Bernd - Abstract:
- Abstract Background Test-retest reproducibility is of utmost importance in follow-up of right ventricular (RV) volumes and function; optimal slice orientation though is not yet known. We compared test-retest reproducibility and intra-/inter-observer variability of right ventricular (RV) volumes and function assessed with short-axis and transverse cardiovascular magnetic resonance (CMR). Methods Eighteen volunteers underwent cine CMR for RV assessment obtaining ventricular coverage in short-axis and transverse slice orientation. Additional 2D phase contrast flow imaging of the main pulmonary artery (MPA) was performed. After complete repositioning repeat acquisitions were performed. Data sets were contoured by two blinded observers. Statistical analysis included Student'st -test, Bland-Altman plots, intra-class correlation coefficient (ICC) and 2-way ANOVA, SEM and minimal detectable difference calculations. Results Heart rates (65.0 ± 7.4 vs. 67.6 ± 9.9 bpm;P = 0.1) and MPA flow (89.8 ± 16.6 vs. 87.2 ± 14.9 mL;P = 0.1) did not differ between imaging sessions. EDV and ESV demonstrated an inter-study bias of 0.4 %[−9.5 %, 10.3 %] and 2.1 %[−12.3 %, 16.4 %] for short-axis and 1.1 %[−7.3 %, 9.4 %] and 0.8 %[−16.0 %, 17.6 %] for transverse orientation, respectively. There was no significant interaction between imaging orientation and interstudy reproducibility (p = 0.395–0.824), intra-observer variability (p = 0.726–0.862) or inter-observer variability (p = 0.447–0.706) byAbstract Background Test-retest reproducibility is of utmost importance in follow-up of right ventricular (RV) volumes and function; optimal slice orientation though is not yet known. We compared test-retest reproducibility and intra-/inter-observer variability of right ventricular (RV) volumes and function assessed with short-axis and transverse cardiovascular magnetic resonance (CMR). Methods Eighteen volunteers underwent cine CMR for RV assessment obtaining ventricular coverage in short-axis and transverse slice orientation. Additional 2D phase contrast flow imaging of the main pulmonary artery (MPA) was performed. After complete repositioning repeat acquisitions were performed. Data sets were contoured by two blinded observers. Statistical analysis included Student'st -test, Bland-Altman plots, intra-class correlation coefficient (ICC) and 2-way ANOVA, SEM and minimal detectable difference calculations. Results Heart rates (65.0 ± 7.4 vs. 67.6 ± 9.9 bpm;P = 0.1) and MPA flow (89.8 ± 16.6 vs. 87.2 ± 14.9 mL;P = 0.1) did not differ between imaging sessions. EDV and ESV demonstrated an inter-study bias of 0.4 %[−9.5 %, 10.3 %] and 2.1 %[−12.3 %, 16.4 %] for short-axis and 1.1 %[−7.3 %, 9.4 %] and 0.8 %[−16.0 %, 17.6 %] for transverse orientation, respectively. There was no significant interaction between imaging orientation and interstudy reproducibility (p = 0.395–0.824), intra-observer variability (p = 0.726–0.862) or inter-observer variability (p = 0.447–0.706) by 2-way ANOVA. Inter-observer agreement by ICC was greater for short axis versus transverse orientation for all parameters (0.769–0.986 vs. 0.625–0.983, respectively). Minimal detectable differences for short axis and transverse orientations were 10.1 mL/11.5 mL for EDV, 8.3 mL/8.4 mL for ESV and 4.1 % vs. 4.7 % for EF, respectively. Conclusion Short-axis and transverse orientation both provide reliable and reproducible measures for follow-up of RV volumes and global function. Therefore, additional transverse SSFP cine CMR may not necessarily be required if performed for the sole purpose of quantitative volumetric RV assessment. … (more)
- Is Part Of:
- Journal of cardiovascular magnetic resonance. Volume 18:Issue 1(2016)
- Journal:
- Journal of cardiovascular magnetic resonance
- Issue:
- Volume 18:Issue 1(2016)
- Issue Display:
- Volume 18, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 18
- Issue:
- 1
- Issue Sort Value:
- 2016-0018-0001-0000
- Page Start:
- 1
- Page End:
- 10
- Publication Date:
- 2016-12
- Subjects:
- Cardiovascular magnetic resonance -- Cardiac output -- Ventricles
Cardiovascular system -- Magnetic resonance imaging -- Periodicals
616.1207548 - Journal URLs:
- http://jcmr-online.com/ ↗
http://www.informaworld.com/1532-429X ↗
http://www.tandfonline.com/ ↗
http://www.dekker.com/servlet/product/productid/JCMR ↗ - DOI:
- 10.1186/s12968-016-0282-x ↗
- Languages:
- English
- ISSNs:
- 1097-6647
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10523.xml