Comparison of LC‐MS/MS vs chemiluminescent microparticle immunoassay in measuring the valproic acid concentration in plasma of epilepsy patients in a new perspective. Issue 1 (15th February 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of LC‐MS/MS vs chemiluminescent microparticle immunoassay in measuring the valproic acid concentration in plasma of epilepsy patients in a new perspective. Issue 1 (15th February 2017)
- Main Title:
- Comparison of LC‐MS/MS vs chemiluminescent microparticle immunoassay in measuring the valproic acid concentration in plasma of epilepsy patients in a new perspective
- Authors:
- Wang, Zhipeng
Yun, Yunlei
Xie, Xinfang
You, Chunhua
Miao, Haijun
Zhang, Feng
Gao, Shouhong
Chen, Wansheng - Abstract:
- Abstract : Objectives: This study was designed to compare the performance of LC‐MS/MS with chemiluminescent microparticle immunoassay (CMIA) for determination of VPA in epilepsy patients in the perspective of metabolites' hepatotoxicity. Method: Samples were collected and then analyzed using both LC‐MS/MS and CMIA. A LO2 cells (normal human hepatic cells) experiment was carried out to confirm VPA metabolites' hepatotoxicity using AST(Aspertate Aminotransferase, AST), ALT(Alanine aminotransferase, ALT) and LDH(lactate dehydrogenase, LDH) in supernate as index. Results: The regression equation analysis showed as LC‐MS/MS=1.0094 CMIA ‐1.8937, with the concordance correlation coefficient of 0.9700, and the CUSUM test proved no significant deviation from linearity ( P >.05). CMIA compared to LC‐MS/MS gave a positive bias of 1.2 μg/mL. In LO2 experiment, VPA and its metabolites groups showed an obvious increment of AST, ALT, and LDH in supernate. Conclusion: The LC‐MS/MS is largely consistent with the CMIA in analytical time and quantification ability for VPA, but the LC‐MS/MS can simultaneously determinate VPA and its metabolites in plasma, and is also a higher cost‐efficiency method in consideration of toxic metabolites monitoring. The overestimation of VPA by CMIA showed no clinical significance. The metabolites 3‐OH‐VPA and 5‐OH‐VPA damage the LO2 cells and the results presented a statistical significance ( P <.05). It is vital to monitor the metabolites' concentrations forAbstract : Objectives: This study was designed to compare the performance of LC‐MS/MS with chemiluminescent microparticle immunoassay (CMIA) for determination of VPA in epilepsy patients in the perspective of metabolites' hepatotoxicity. Method: Samples were collected and then analyzed using both LC‐MS/MS and CMIA. A LO2 cells (normal human hepatic cells) experiment was carried out to confirm VPA metabolites' hepatotoxicity using AST(Aspertate Aminotransferase, AST), ALT(Alanine aminotransferase, ALT) and LDH(lactate dehydrogenase, LDH) in supernate as index. Results: The regression equation analysis showed as LC‐MS/MS=1.0094 CMIA ‐1.8937, with the concordance correlation coefficient of 0.9700, and the CUSUM test proved no significant deviation from linearity ( P >.05). CMIA compared to LC‐MS/MS gave a positive bias of 1.2 μg/mL. In LO2 experiment, VPA and its metabolites groups showed an obvious increment of AST, ALT, and LDH in supernate. Conclusion: The LC‐MS/MS is largely consistent with the CMIA in analytical time and quantification ability for VPA, but the LC‐MS/MS can simultaneously determinate VPA and its metabolites in plasma, and is also a higher cost‐efficiency method in consideration of toxic metabolites monitoring. The overestimation of VPA by CMIA showed no clinical significance. The metabolites 3‐OH‐VPA and 5‐OH‐VPA damage the LO2 cells and the results presented a statistical significance ( P <.05). It is vital to monitor the metabolites' concentrations for VAP's clinical safety application, and now is the occasion that laboratory and clinic consider the LC‐MS/MS method as a more advantageous alternative to CMIA method in therapeutic monitoring of VPA. … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 32:Issue 1(2018)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 32:Issue 1(2018)
- Issue Display:
- Volume 32, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 32
- Issue:
- 1
- Issue Sort Value:
- 2018-0032-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-02-15
- Subjects:
- chemiluminescent microparticle immunoassay -- LC‐MS/MS -- LO2 experiment -- VPA and its metabolites
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.22157 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10504.xml