Postextraction Dental Implant in the Aesthetic Zone, Socket Shield Technique Versus Conventional Protocol. Issue 4 (June 2018)
- Record Type:
- Journal Article
- Title:
- Postextraction Dental Implant in the Aesthetic Zone, Socket Shield Technique Versus Conventional Protocol. Issue 4 (June 2018)
- Main Title:
- Postextraction Dental Implant in the Aesthetic Zone, Socket Shield Technique Versus Conventional Protocol
- Authors:
- Bramanti, Ennio
Norcia, Antonio
Cicciù, Marco
Matacena, Giada
Cervino, Gabriele
Troiano, Giuseppe
Zhurakivska, Khrystyna
Laino, Luigi - Abstract:
- Abstract : Abstract: The aim of this randomized controlled trial was to evaluate the survival rate, the marginal bone level, and the aesthetic outcome; at 3 years' follow-up, of dental implants placed into a high-esthetic aesthetic zone by comparing 2 techniques of postextraction implant with immediate loading: the socket shied technique and the conventional insertion technique. Several clinical studies suggested that the avulsion of a dental element causes dimensional alterations of both soft and hard tissues at the postextractive site. To increase the aesthetic outcomes, the "socket-shield technique" has been proposed. This method involves maintaining the vestibular root portion and immediate insertion of the dental implant in close proximity to the root. Patients enrolled in this study were randomized to receive a postextraction implant in the aesthetic zone, either with the socket shied technique or with the conventional insertion technique. Implant survival, marginal bone level, and the pink aesthetic score were the outcomes evaluated. Implant survival rate was 100% in both the groups at 3 years. Implants inserted with the socket shield technique showed better values of both marginal bone level and pink aesthetic score ( P < 0.05). Although such preliminary results need to be further confirmed, the socket shield technique seems to be a safe surgical technique that allows an implant rehabilitation characterized by better aesthetic outcomes.
- Is Part Of:
- Journal of craniofacial surgery. Volume 29:Issue 4(2018)
- Journal:
- Journal of craniofacial surgery
- Issue:
- Volume 29:Issue 4(2018)
- Issue Display:
- Volume 29, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 29
- Issue:
- 4
- Issue Sort Value:
- 2018-0029-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-06
- Subjects:
- Aesthetic implant -- dental implant -- guided bone regeneration -- immediate loading -- implantology -- postextraction implant -- socket shield technique
Facial bones -- Surgery -- Periodicals
Skull -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
617.52 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00001665-000000000-00000 ↗
http://www.jcraniofacialsurgery.com ↗
http://journals.lww.com/jcraniofacialsurgery/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/SCS.0000000000004419 ↗
- Languages:
- English
- ISSNs:
- 1049-2275
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.476000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10500.xml