Development and Validation of a GC-MS Method for the Detection and Quantification of Clotiapine in Blood and Urine Specimens and Application to a Postmortem Case. (7th July 2015)
- Record Type:
- Journal Article
- Title:
- Development and Validation of a GC-MS Method for the Detection and Quantification of Clotiapine in Blood and Urine Specimens and Application to a Postmortem Case. (7th July 2015)
- Main Title:
- Development and Validation of a GC-MS Method for the Detection and Quantification of Clotiapine in Blood and Urine Specimens and Application to a Postmortem Case
- Authors:
- Mannocchi, Giulio
Pantano, Flaminia
Tittarelli, Roberta
Catanese, Miriam
Umani Ronchi, Federica
Busardò, Francesco Paolo - Other Names:
- Wang Haopeng Academic Editor.
- Abstract:
- Abstract : Introduction . Clotiapine is an atypical antipsychotic of the dibenzothiazepine class introduced in a few European countries since 1970, efficient in treatment-resistant schizophrenic patients. There is little published data on the therapeutic and toxic concentrations of this drug. Aims . The aim of the present study is the development and validation of a method that allows the detection and quantification of clotiapine in blood and urine specimens by gas chromatography-mass spectrometry (GC-MS). Methods . Validation was performed working on spiked postmortem blood and urine samples. Samples were extracted with liquid-liquid extraction (LLE) technique at pH 8.5 with n-hexane/dichloromethane (85/15 v/v) and analysis was followed by GC-MS. Methadone-d9 was used as internal standard. Results . The limit of detection (LOD) was 1.2 and 1.3 ng/mL for urine and blood, respectively, while the lower limit of quantification (LLOQ) was 3.9 and 4.3 ng/mL, respectively. Linearity, precision, selectivity, accuracy, and recovery were also determined. The method was applied to a postmortem case. The blood and urine clotiapine concentrations were 1.32 and 0.49 μ g/mL, respectively. Conclusions . A reliable GC-MS method for the detection and quantification of clotiapine in blood and urine samples has been developed and fully validated and then applied to a postmortem case.
- Is Part Of:
- International journal of analytical chemistry. Volume 2015(2015)
- Journal:
- International journal of analytical chemistry
- Issue:
- Volume 2015(2015)
- Issue Display:
- Volume 2015, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 2015
- Issue:
- 2015
- Issue Sort Value:
- 2015-2015-2015-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07-07
- Subjects:
- Chemistry, Analytic -- Periodicals
543.05 - Journal URLs:
- https://www.hindawi.com/journals/ijac/ ↗
- DOI:
- 10.1155/2015/972480 ↗
- Languages:
- English
- ISSNs:
- 1687-8760
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 10484.xml