Correlation of cone beam CT-derived bone density parameters with primary implant stability assessed by peak insertion torque and periotest in the maxilla. Issue 3 (March 2019)
- Record Type:
- Journal Article
- Title:
- Correlation of cone beam CT-derived bone density parameters with primary implant stability assessed by peak insertion torque and periotest in the maxilla. Issue 3 (March 2019)
- Main Title:
- Correlation of cone beam CT-derived bone density parameters with primary implant stability assessed by peak insertion torque and periotest in the maxilla
- Authors:
- Hakim, Samer G.
Glanz, Julia
Ofer, Markus
Steller, Daniel
Sieg, Peter - Abstract:
- Abstract: Purpose: Primary implant stability is crucial to osseointegration. The aim of this study was to assess correlation of preoperative radiologic parameters with intraoperatively obtained biomechanical tests in the maxilla. Materials and methods: A total of 259 implants were inserted in the maxilla of 99 patients. Cone-beam computed tomography (CBCT)-derived Hounsfield units (HU), voxel grey values and computed tomography mental index (CTMI) performed preoperatively were correlated with insertion torque and Periotest (obtained intraoperatively and 12 weeks later) to assess their prognostic value for primary implant stability. Results: Voxel grey values and insertion torque showed a low correlation ( r = 0.329, p = 1.055 × 10 − 7 ). Likewise, a low correlation was found between HU measured preoperatively and insertion torque as well as intraoperative Periotest values ( r = 0.297, p = 4 × 10 − 6 and r = − 0.234, p = 4.35 × 10 − 4, respectively). A moderate correlation could, however, be assessed between insertion torque and intraoperative as well as Periotest values 12 weeks later. ( r = −0.555, p = 1.022 × 10 − 20 and −0.465. p = 1.150 × 10 − 13 ). On contrast, a high correlation was observed between the voxel grey values of CBCT and related HU ( r = 0.710, p = 6.486 × 10 − 37 ) so that a conversion from grey values into HU could be suggested. According to regression analysis, an intraoperative negative Periotest value could be expected at an insertion torqueAbstract: Purpose: Primary implant stability is crucial to osseointegration. The aim of this study was to assess correlation of preoperative radiologic parameters with intraoperatively obtained biomechanical tests in the maxilla. Materials and methods: A total of 259 implants were inserted in the maxilla of 99 patients. Cone-beam computed tomography (CBCT)-derived Hounsfield units (HU), voxel grey values and computed tomography mental index (CTMI) performed preoperatively were correlated with insertion torque and Periotest (obtained intraoperatively and 12 weeks later) to assess their prognostic value for primary implant stability. Results: Voxel grey values and insertion torque showed a low correlation ( r = 0.329, p = 1.055 × 10 − 7 ). Likewise, a low correlation was found between HU measured preoperatively and insertion torque as well as intraoperative Periotest values ( r = 0.297, p = 4 × 10 − 6 and r = − 0.234, p = 4.35 × 10 − 4, respectively). A moderate correlation could, however, be assessed between insertion torque and intraoperative as well as Periotest values 12 weeks later. ( r = −0.555, p = 1.022 × 10 − 20 and −0.465. p = 1.150 × 10 − 13 ). On contrast, a high correlation was observed between the voxel grey values of CBCT and related HU ( r = 0.710, p = 6.486 × 10 − 37 ) so that a conversion from grey values into HU could be suggested. According to regression analysis, an intraoperative negative Periotest value could be expected at an insertion torque of 40 N/cm upwards. Conclusion: CBCT-based bone density parameters correlate with each other and allow conversion of grey scales into HU preoperatively. Both insertion torque and Periotest showed a significant correlation which enables regression analysis to predict implant stability for related insertion torque. On contrast, for HU the distribution curves do not allow a reliable assignment into certain Periotest values. … (more)
- Is Part Of:
- Journal of cranio-maxillofacial surgery. Volume 47:Issue 3(2019)
- Journal:
- Journal of cranio-maxillofacial surgery
- Issue:
- Volume 47:Issue 3(2019)
- Issue Display:
- Volume 47, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 47
- Issue:
- 3
- Issue Sort Value:
- 2019-0047-0003-0000
- Page Start:
- 461
- Page End:
- 467
- Publication Date:
- 2019-03
- Subjects:
- Bone mineral density -- Cone beam CT -- Dental implants -- Insertion torque -- Maxilla -- Resonance frequency analysis
Skull -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Maxilla -- surgery -- Periodicals
Face -- surgery -- Periodicals
Skull -- surgery -- Periodicals
Oral Surgical Procedures -- Periodicals
Reconstructive Surgical Procedures -- Periodicals
Surgery, Plastic -- Periodicals
Surgery, Oral -- Periodicals
Electronic journals
617.514 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10105182 ↗
http://firstsearch.oclc.org ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10105182 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcms.2019.01.002 ↗
- Languages:
- English
- ISSNs:
- 1010-5182
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.482000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10444.xml