Biomechanical testing of different posterior fusion devices on lumbar spinal range of motion. (February 2019)
- Record Type:
- Journal Article
- Title:
- Biomechanical testing of different posterior fusion devices on lumbar spinal range of motion. (February 2019)
- Main Title:
- Biomechanical testing of different posterior fusion devices on lumbar spinal range of motion
- Authors:
- Hartmann, Frank
Nusselt, Thomas
Maier, Gerrit
Rommens, Pol Maria
Gercek, Erol - Abstract:
- Abstract: Background: Recent minimal-invasive posterior fusion devices are supposed to provide stability and obtain fusion in combination with interbody cages in the instrumented segment. The aim of the present study is to evaluate the primary stability of two minimal-invasive posterior prototypes compared to an established spinous process plate and standard pedicle screw instrumentation. Methods: Seven fresh frozen human cadaver lumbar spines (L2–L5) were tested in a spinal testing device with a moment of 7.5 Nm. Spinal stability was determined as mean range of motion (RoM) in the segment L3/L4 during extension-flexion, lateral bending and axial rotation. The RoM was measured during five conditions: 1. intact; 2. working prototype composed of an interspinous device and process plates; 3. an established spinous process fixation device 4. working prototype of facet fixation and 5. pedicle screw fixation. Findings: All devices caused a significant reduction of RoM during extension-flexion. The RoM during lateral bending was significantly reduced to 37% (of intact) by pedicle screws and 68% by facet fixation prototype. During axial rotation the RoM was significantly reduced to 52% by pedicle screws and to 86% by facet fixation prototype. The other devices had no significant influence on RoM during lateral bending and axial rotation. Interpretation: The facet fixation prototype provided less primary stability compared to pedicle screws, but had significant advantages overAbstract: Background: Recent minimal-invasive posterior fusion devices are supposed to provide stability and obtain fusion in combination with interbody cages in the instrumented segment. The aim of the present study is to evaluate the primary stability of two minimal-invasive posterior prototypes compared to an established spinous process plate and standard pedicle screw instrumentation. Methods: Seven fresh frozen human cadaver lumbar spines (L2–L5) were tested in a spinal testing device with a moment of 7.5 Nm. Spinal stability was determined as mean range of motion (RoM) in the segment L3/L4 during extension-flexion, lateral bending and axial rotation. The RoM was measured during five conditions: 1. intact; 2. working prototype composed of an interspinous device and process plates; 3. an established spinous process fixation device 4. working prototype of facet fixation and 5. pedicle screw fixation. Findings: All devices caused a significant reduction of RoM during extension-flexion. The RoM during lateral bending was significantly reduced to 37% (of intact) by pedicle screws and 68% by facet fixation prototype. During axial rotation the RoM was significantly reduced to 52% by pedicle screws and to 86% by facet fixation prototype. The other devices had no significant influence on RoM during lateral bending and axial rotation. Interpretation: The facet fixation prototype provided less primary stability compared to pedicle screws, but had significant advantages over spinous process fixation techniques. The results encourage further testing of this implant as a minimal-invasive approach for posterior fixation. Highlights: Spinous process fixation lacks stability during lateral bending and axial rotation. Spinous process fixation requires additional interbody or posterior fixation. Facet fixation provides higher stability, but is inferior to pedicle screws. Facet fixation is a promising minimal-invasive approach for posterior fixation. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 62(2019)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 62(2019)
- Issue Display:
- Volume 62, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 62
- Issue:
- 2019
- Issue Sort Value:
- 2019-0062-2019-0000
- Page Start:
- 121
- Page End:
- 126
- Publication Date:
- 2019-02
- Subjects:
- Spinous process fixation -- Lumbar spinal stenosis -- Biomechanics -- Facet fixation -- Pedicle screw fixation
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2019.01.012 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10451.xml