Multi-atlas cardiac PET segmentation. (February 2019)
- Record Type:
- Journal Article
- Title:
- Multi-atlas cardiac PET segmentation. (February 2019)
- Main Title:
- Multi-atlas cardiac PET segmentation
- Authors:
- Kim, Sally Ji Who
Seo, Seongho
Kim, Hyeon Sik
Kim, Dong-Yeon
Kang, Keon Wook
Min, Jung-Joon
Lee, Jae Sung - Abstract:
- Highlights: A multi-atlas based segmentation method for cardiac PET and SPECT images. Remarkably different perfusion between single-atlas and multi-atlas based ROIs. High correlation results between multi-atlas based and manual segmentations. Abstract: Purpose: We propose a multi-atlas based segmentation method for cardiac PET and SPECT images to deal with the high variability of tracer uptake characteristics in myocardium. In addition, we verify its performance by comparing it to the manual segmentation and single-atlas based approach, using dynamic myocardial PET. Methods: Twelve left coronary artery ligated SD rats underwent ([ 18 F]fluoropentyl) triphenylphosphonium salt PET/CT scans. Atlas-based segmentation is based on the spatial normalized template with pre-defined region-of-interest (ROI) for each anatomical or functional structure. To generate multiple left ventricular (LV) atlases, each LV image was segmented manually and divided into angular segments. The segmentation methods performances were compared in regional count information using leave-one-out cross-validation. Additionally, the polar-maps of kinetic parameters were estimated. Results: In all images, the highest r 2 template yielded the lowest root-mean-square error (RMSE) between the source image and the best-matching templates ranged between 0.91–0.97 and 0.06–0.11, respectively. The single-atlas and multi-atlas based ROIs yielded remarkably different perfusion distributions: only the multi-atlas basedHighlights: A multi-atlas based segmentation method for cardiac PET and SPECT images. Remarkably different perfusion between single-atlas and multi-atlas based ROIs. High correlation results between multi-atlas based and manual segmentations. Abstract: Purpose: We propose a multi-atlas based segmentation method for cardiac PET and SPECT images to deal with the high variability of tracer uptake characteristics in myocardium. In addition, we verify its performance by comparing it to the manual segmentation and single-atlas based approach, using dynamic myocardial PET. Methods: Twelve left coronary artery ligated SD rats underwent ([ 18 F]fluoropentyl) triphenylphosphonium salt PET/CT scans. Atlas-based segmentation is based on the spatial normalized template with pre-defined region-of-interest (ROI) for each anatomical or functional structure. To generate multiple left ventricular (LV) atlases, each LV image was segmented manually and divided into angular segments. The segmentation methods performances were compared in regional count information using leave-one-out cross-validation. Additionally, the polar-maps of kinetic parameters were estimated. Results: In all images, the highest r 2 template yielded the lowest root-mean-square error (RMSE) between the source image and the best-matching templates ranged between 0.91–0.97 and 0.06–0.11, respectively. The single-atlas and multi-atlas based ROIs yielded remarkably different perfusion distributions: only the multi-atlas based segmentation showed equivalent high correlation results ( r 2 = 0.92) with the manual segmentation compared with the single-atlas based ( r 2 = 0.88). The high perfusion value underestimation was remarkable in single-atlas based segmentation. Conclusions: The main advantage of the proposed multi-atlas based cardiac segmentation method is that it does not require any prior information on the tracer distribution to be incorporated into the image segmentation algorithms. Therefore, the same procedure suggested here is applicable to any other cardiac PET or SPECT imaging agents without modification. … (more)
- Is Part Of:
- Physica medica. Volume 58(2019)
- Journal:
- Physica medica
- Issue:
- Volume 58(2019)
- Issue Display:
- Volume 58, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 58
- Issue:
- 2019
- Issue Sort Value:
- 2019-0058-2019-0000
- Page Start:
- 32
- Page End:
- 39
- Publication Date:
- 2019-02
- Subjects:
- Segmentation -- Myocardial PET -- Atlas -- Quantification
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.01.003 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10443.xml