Clinical evaluation of a transmission detector system and comparison with a homogeneous 3D phantom dosimeter. (February 2019)
- Record Type:
- Journal Article
- Title:
- Clinical evaluation of a transmission detector system and comparison with a homogeneous 3D phantom dosimeter. (February 2019)
- Main Title:
- Clinical evaluation of a transmission detector system and comparison with a homogeneous 3D phantom dosimeter
- Authors:
- Giglioli, Francesca Romana
Gallio, Elena
Franco, Pierfrancesco
Badellino, Serena
Ricardi, Umberto
Fiandra, Christian - Abstract:
- Highlights: No correlation was found between Dolphin DVHs analysis and Delta 4 γ passing rate. A value of 10.7% ± 0.7% was found for detector attenuation. Correlation was found between γ inside the PTV (Dolphin) and clinical decision. Abstract: Purpose: To evaluate the performances of the Dolphin system for pre-treatment verification (IBA Dosimetry, Schwarzenbruck, Germany) based on transmission measurements, employing a clinical perspective. Methods and materials: Fifty treatment plans were verified by Dolphin and Delta 4 detectors (Scandidos, Uppsala, Sweden) during the same session and subsequently by the Delta 4 itself. The attenuation factor of the transmission detector (required for on-line dosimetry) was evaluated by comparing Delta 4 measurements with and without Dolphin. Gamma evaluation was performed to compare the plan dose with the one delivered in case of Delta 4 and Dolphin (gamma analysis within the structures). Dose–volume based parameters for PTV and OARs doses were considered for Compass calculation and Dolphin reconstruction and clinical decisions were made by two expert physicians in order to assess the "pass", "fail" or "evaluate" grade of the treatment plans. A statistical analysis was performed to investigate the eventual correlation between Delta 4 gamma analysis and Dolphin clinical evaluation. Results: A value of 10.7% ± 0.7% was found for detector attenuation. No patients were classified as "fail" by the two instruments as well as by physicians. NoHighlights: No correlation was found between Dolphin DVHs analysis and Delta 4 γ passing rate. A value of 10.7% ± 0.7% was found for detector attenuation. Correlation was found between γ inside the PTV (Dolphin) and clinical decision. Abstract: Purpose: To evaluate the performances of the Dolphin system for pre-treatment verification (IBA Dosimetry, Schwarzenbruck, Germany) based on transmission measurements, employing a clinical perspective. Methods and materials: Fifty treatment plans were verified by Dolphin and Delta 4 detectors (Scandidos, Uppsala, Sweden) during the same session and subsequently by the Delta 4 itself. The attenuation factor of the transmission detector (required for on-line dosimetry) was evaluated by comparing Delta 4 measurements with and without Dolphin. Gamma evaluation was performed to compare the plan dose with the one delivered in case of Delta 4 and Dolphin (gamma analysis within the structures). Dose–volume based parameters for PTV and OARs doses were considered for Compass calculation and Dolphin reconstruction and clinical decisions were made by two expert physicians in order to assess the "pass", "fail" or "evaluate" grade of the treatment plans. A statistical analysis was performed to investigate the eventual correlation between Delta 4 gamma analysis and Dolphin clinical evaluation. Results: A value of 10.7% ± 0.7% was found for detector attenuation. No patients were classified as "fail" by the two instruments as well as by physicians. No correlation was found between the Delta 4 gamma metric and physician classification; conversely, a significant correlation was observed for Dolphin between the numbers of points with gamma ≥1 (gamma failure rate, as evaluated by the Dolphin) in the PTV area and clinical decision. Conclusion: The Dolphin system demonstrated to be an accurate detector for pre-treatment purposes and could be used as a clinical decision making tool for plan acceptance. … (more)
- Is Part Of:
- Physica medica. Volume 58(2019)
- Journal:
- Physica medica
- Issue:
- Volume 58(2019)
- Issue Display:
- Volume 58, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 58
- Issue:
- 2019
- Issue Sort Value:
- 2019-0058-2019-0000
- Page Start:
- 159
- Page End:
- 164
- Publication Date:
- 2019-02
- Subjects:
- IMRT -- QA -- Dosimetry -- Gamma metric -- Pre-treatment verification
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.01.016 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10443.xml