Floor and environmental contamination during glove disposal. Issue 3 (March 2019)
- Record Type:
- Journal Article
- Title:
- Floor and environmental contamination during glove disposal. Issue 3 (March 2019)
- Main Title:
- Floor and environmental contamination during glove disposal
- Authors:
- Munoz-Gutierrez, K.M.
Canales, R.A.
Reynolds, K.A.
Verhougstraete, M.P. - Abstract:
- Summary: Background: Evidence suggests that doffing and possibly disposal of used personal protective equipment (PPE) can lead to environmental contamination. Aim: To ascertain the potential for site and floor contamination when medical gloves are inappropriately disposed. Methods: Fifteen healthcare workers (HCWs) disposed of gloves inoculated with bacteriophage and a chemical dye into a wastebasket, located 1.22 m away. Following each trial, designated sample areas were visually inspected with a blacklight for fluorescent dye stains and swabbed with a 3M Letheen Broth sponge to quantify the bacteriophage. Findings: The area closest to the participant (<0.30 m) had the highest bacteriophage concentrations (geomean: 6.9 × 10 3 pfu/100 cm 2 ; range: 8.07 to 3.93 × 10 7 pfu/100 cm 2 ). Bacteriophage concentrations were significantly higher ( P < 0.05) in areas ≤0.61 m compared to >0.61 m from the HCWs. Although the farthest distances (1.22–1.52 m) resulted in 14% bacteriophage- and 4% fluorescent dye-positive occurrences, there was no significant difference ( P = 0.069) between the tracers. The bacteriophage and chemical dye indicate highest environmental contamination nearest the HCWs and both tracers could be appropriate for PPE disposal training. Conclusion: HCWs use gloves every workday and potentially could contaminate surrounding surfaces and floors, during improper disposal practices. Therefore, proper disposal techniques are required to minimize pathogenSummary: Background: Evidence suggests that doffing and possibly disposal of used personal protective equipment (PPE) can lead to environmental contamination. Aim: To ascertain the potential for site and floor contamination when medical gloves are inappropriately disposed. Methods: Fifteen healthcare workers (HCWs) disposed of gloves inoculated with bacteriophage and a chemical dye into a wastebasket, located 1.22 m away. Following each trial, designated sample areas were visually inspected with a blacklight for fluorescent dye stains and swabbed with a 3M Letheen Broth sponge to quantify the bacteriophage. Findings: The area closest to the participant (<0.30 m) had the highest bacteriophage concentrations (geomean: 6.9 × 10 3 pfu/100 cm 2 ; range: 8.07 to 3.93 × 10 7 pfu/100 cm 2 ). Bacteriophage concentrations were significantly higher ( P < 0.05) in areas ≤0.61 m compared to >0.61 m from the HCWs. Although the farthest distances (1.22–1.52 m) resulted in 14% bacteriophage- and 4% fluorescent dye-positive occurrences, there was no significant difference ( P = 0.069) between the tracers. The bacteriophage and chemical dye indicate highest environmental contamination nearest the HCWs and both tracers could be appropriate for PPE disposal training. Conclusion: HCWs use gloves every workday and potentially could contaminate surrounding surfaces and floors, during improper disposal practices. Therefore, proper disposal techniques are required to minimize pathogen transmission by establishing industry-wide policies, adequate training, and education to HCWs. … (more)
- Is Part Of:
- Journal of hospital infection. Volume 101:Issue 3(2019)
- Journal:
- Journal of hospital infection
- Issue:
- Volume 101:Issue 3(2019)
- Issue Display:
- Volume 101, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 101
- Issue:
- 3
- Issue Sort Value:
- 2019-0101-0003-0000
- Page Start:
- 347
- Page End:
- 353
- Publication Date:
- 2019-03
- Subjects:
- Glove disposal -- Environmental contamination -- Personal protective equipment -- Biological tracers -- Floor contamination -- Hospital
Cross infection -- Periodicals
Cross infection -- Prevention -- Periodicals
Nosocomial infections -- Periodicals
Nosocomial infections -- Prevention -- Periodicals
Cross Infection -- Periodicals
Cross Infection -- prevention & control -- Periodicals
Infection Control -- Periodicals
Electronic journals
614.44 - Journal URLs:
- http://www.harcourt-international.com/journals ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01956701 ↗
http://www.sciencedirect.com/science/journal/01956701 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jhin.2018.10.015 ↗
- Languages:
- English
- ISSNs:
- 0195-6701
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5003.285000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10445.xml