Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery: A randomised double-blind controlled trial. Issue 5 (May 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery: A randomised double-blind controlled trial. Issue 5 (May 2018)
- Main Title:
- Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery
- Authors:
- Sng, Ban Leong
Du, Wei
Lee, Man Xin
Ithnin, Farida
Mathur, Deepak
Leong, Wan Ling
Sultana, Rehena
Han, Nian-Lin R.
Sia, Alex Tiong Heng - Abstract:
- Abstract : BACKGROUND: Hypotension is a common side effect of spinal anaesthesia during caesarean delivery and is associated with maternal and foetal adverse effects. We developed an updated double intravenous vasopressor automated (DIVA) system that administers phenylephrine or ephedrine based on continuous noninvasive haemodynamic monitoring using the Nexfin device. OBJECTIVE: The aim of our present study is to compare the performance and reliability of the DIVA system against Manual Vasopressor Bolus administration. DESIGN: A randomised, double-blind controlled trial. SETTING: Single-centre, KK Women's and Children's Hospital, Singapore. PATIENTS: Two hundred and thirty-six healthy women undergoing elective caesarean delivery under spinal anaesthesia. MAIN OUTCOME MEASURES: The primary outcome was the incidence of maternal hypotension. The secondary outcome measures were reactive hypertension, total vasopressor requirement and maternal and neonatal outcomes. RESULTS: The DIVA group had a significantly lower incidence of maternal hypotension, with 39.3% (46 of 117) patients having any SBP reading less than 80% of baseline compared with 57.5% (65 of 113) in the manual vasopressor bolus group ( P = 0.008). The DIVA group also had fewer hypotensive episodes than the manual vasopressor bolus group (4.67 versus 7.77%; P < 0.0001). There was no difference in the incidence of reactive hypertension or the total vasopressor requirement. The DIVA group had less wobble in systemAbstract : BACKGROUND: Hypotension is a common side effect of spinal anaesthesia during caesarean delivery and is associated with maternal and foetal adverse effects. We developed an updated double intravenous vasopressor automated (DIVA) system that administers phenylephrine or ephedrine based on continuous noninvasive haemodynamic monitoring using the Nexfin device. OBJECTIVE: The aim of our present study is to compare the performance and reliability of the DIVA system against Manual Vasopressor Bolus administration. DESIGN: A randomised, double-blind controlled trial. SETTING: Single-centre, KK Women's and Children's Hospital, Singapore. PATIENTS: Two hundred and thirty-six healthy women undergoing elective caesarean delivery under spinal anaesthesia. MAIN OUTCOME MEASURES: The primary outcome was the incidence of maternal hypotension. The secondary outcome measures were reactive hypertension, total vasopressor requirement and maternal and neonatal outcomes. RESULTS: The DIVA group had a significantly lower incidence of maternal hypotension, with 39.3% (46 of 117) patients having any SBP reading less than 80% of baseline compared with 57.5% (65 of 113) in the manual vasopressor bolus group ( P = 0.008). The DIVA group also had fewer hypotensive episodes than the manual vasopressor bolus group (4.67 versus 7.77%; P < 0.0001). There was no difference in the incidence of reactive hypertension or the total vasopressor requirement. The DIVA group had less wobble in system performance. Maternal and neonatal outcomes were similar. CONCLUSION: The DIVA system achieved better control of maternal blood pressure after spinal anaesthesia than manual vasopressor bolus administration. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT02277730. … (more)
- Is Part Of:
- European journal of anaesthesiology. Volume 35:Issue 5(2018:May)
- Journal:
- European journal of anaesthesiology
- Issue:
- Volume 35:Issue 5(2018:May)
- Issue Display:
- Volume 35, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 35
- Issue:
- 5
- Issue Sort Value:
- 2018-0035-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-05
- Subjects:
- Anesthesiology -- Periodicals
Anesthesiology -- Periodicals
Anesthésiologie -- Périodiques
Anesthesiology
Periodicals
Electronic journals
617.96 - Journal URLs:
- http://journals.lww.com/ejanaesthesiology/pages/default.aspx ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2346/issues ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=eja ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00003643-000000000-00000 ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0265-0215 ↗ - DOI:
- 10.1097/EJA.0000000000000779 ↗
- Languages:
- English
- ISSNs:
- 0265-0215
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.722200
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10429.xml