Motion response of a polycrystalline diamond adaptive axis of rotation cervical total disc arthroplasty. (February 2019)
- Record Type:
- Journal Article
- Title:
- Motion response of a polycrystalline diamond adaptive axis of rotation cervical total disc arthroplasty. (February 2019)
- Main Title:
- Motion response of a polycrystalline diamond adaptive axis of rotation cervical total disc arthroplasty
- Authors:
- Havey, Robert M.
Khayatzadeh, Saeed
Voronov, Leonard I.
Blank, Kenneth R.
Carandang, Gerard
Harding, David P.
Patwardhan, Avinash G. - Abstract:
- Abstract: Background: Cervical fusion is associated with adjacent segment degeneration. Cervical disc arthroplasty is considered an alternative to reduce risk of adjacent segment disease. Kinematics after arthroplasty should closely replicate healthy in vivo kinematics to reduce adjacent segment stresses. The purpose of this study was to assess the kinematics of a polycrystalline diamond cervical disc prosthesis. Methods: Nine cadaveric C3–T1 spines were tested intact and after one (C5–C6) and two level (C5–C7) arthroplasty (Triadyme-C, Dymicron Inc., Orem, UT, USA). Kinematics were evaluated in flexion-extension, lateral bending, and axial rotation. Findings: Prosthesis placement at C5–C6 and C6–C7 was 0.5 mm anterior and 0.6 mm posterior to midline respectively. C5–C6 flexion-extension motion was 12.8° intact and 10.5° after arthroplasty. C6–C7 flexion-extension motion was 10.0 and 11.4° after arthroplasty. C5–C6 lateral bending reduced from 8.5 to 3.7° after arthroplasty and at C6–C7 from 7.5 to 5.1°. C5–C6 axial rotation decreased from 10.4 to 6.2° after arthroplasty and at C6–C7 from 7.8 to 5.3°. Segmental lordosis increased by 4.2°, and middle disc height by 1.4 mm after arthroplasty. Change in center of rotation from intact to arthroplasty averaged 0.9 mm posteriorly and 0.1 mm caudally at C5–C6, and 1.4 mm posteriorly and 0.3 mm cranially at C6–C7. Interpretation: The cervical disc arthroplasty evaluated restored flexion-extension motion to intact levels andAbstract: Background: Cervical fusion is associated with adjacent segment degeneration. Cervical disc arthroplasty is considered an alternative to reduce risk of adjacent segment disease. Kinematics after arthroplasty should closely replicate healthy in vivo kinematics to reduce adjacent segment stresses. The purpose of this study was to assess the kinematics of a polycrystalline diamond cervical disc prosthesis. Methods: Nine cadaveric C3–T1 spines were tested intact and after one (C5–C6) and two level (C5–C7) arthroplasty (Triadyme-C, Dymicron Inc., Orem, UT, USA). Kinematics were evaluated in flexion-extension, lateral bending, and axial rotation. Findings: Prosthesis placement at C5–C6 and C6–C7 was 0.5 mm anterior and 0.6 mm posterior to midline respectively. C5–C6 flexion-extension motion was 12.8° intact and 10.5° after arthroplasty. C6–C7 flexion-extension motion was 10.0 and 11.4° after arthroplasty. C5–C6 lateral bending reduced from 8.5 to 3.7° after arthroplasty and at C6–C7 from 7.5 to 5.1°. C5–C6 axial rotation decreased from 10.4 to 6.2° after arthroplasty and at C6–C7 from 7.8 to 5.3°. Segmental lordosis increased by 4.2°, and middle disc height by 1.4 mm after arthroplasty. Change in center of rotation from intact to arthroplasty averaged 0.9 mm posteriorly and 0.1 mm caudally at C5–C6, and 1.4 mm posteriorly and 0.3 mm cranially at C6–C7. Interpretation: The cervical disc arthroplasty evaluated restored flexion-extension motion to intact levels and moderately increased segmental stiffness. Disc height increased by up to 1.5 mm and segmental lordosis by 4.2°. The unique prosthesis design allowed the axis of rotation after arthroplasty to closely mimic the native location. Highlights: The polycrystalline diamond cervical arthroplasty restored intact levels of flexion-extension. Arthroplasty moderately increased segmental stiffness. Arthroplasty had minimal effect on neutral zone and hysteresis. Arthroplasty increased disc height (1.0 to 1.5 mm) and segmental lordosis (4.2°) on average. The arthroplasty design allowed the center of rotation to closely mimic that of the native disc. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 62(2019)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 62(2019)
- Issue Display:
- Volume 62, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 62
- Issue:
- 2019
- Issue Sort Value:
- 2019-0062-2019-0000
- Page Start:
- 34
- Page End:
- 41
- Publication Date:
- 2019-02
- Subjects:
- Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2018.12.023 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10423.xml