Assessing the feasibility of single target radiosurgery quality assurance with portal dosimetry. Issue 5 (1st April 2019)
- Record Type:
- Journal Article
- Title:
- Assessing the feasibility of single target radiosurgery quality assurance with portal dosimetry. Issue 5 (1st April 2019)
- Main Title:
- Assessing the feasibility of single target radiosurgery quality assurance with portal dosimetry
- Authors:
- Covington, Elizabeth L.
Snyder, Jesse D.
Wu, Xingen
Cardan, Rex A.
Popple, Richard A. - Abstract:
- Abstract: Purpose: To assess the feasibility of using portal dosimetry (PD) for pre‐treatment quality assurance of single target, flattening filter free (FFF), volumetric arc therapy intracranial radiosurgery plans. Methods: A PD algorithm was created for a 10X FFF beam on a Varian Edge linear accelerator (Varian Inc, Palo Alto, CA, USA). Treatment plans that were previously evaluated with Gafchromic EBT‐XD (Ashland, Bridgewater, NJ, USA) film were measured via PD and analyzed with the ARIA Portal Dosimetry workspace. Absolute dose evaluation for film and PD was done by computing the mean dose in the region receiving greater than or equal to 90% of the max dose and comparing to the mean dose in the same region calculated by the treatment planning system (TPS). Gamma analysis with 10% threshold and 3%/2 mm passing criteria was performed on film and portal images. Results: Thirty‐six PD verification plans were delivered and analyzed. The average PD to TPS dose was 0.989 ± 0.01 while film to TPS dose was 1.026 ± 0.01. All PD plans passed the gamma analysis with 100% of points having gamma <1. Overall, PD to TPS dose agreement was found to be target size dependent. As target size decreases, PD to TPS dose ratio decreased from 1.004 for targets with diameters between 15–31 mm and 0.978 for targets with diameters less than 15 mm. Conclusion: The agreement of PD to TPS mean dose in the high dose region was found to be dependent on target size. Film measurements did not exhibit sizeAbstract: Purpose: To assess the feasibility of using portal dosimetry (PD) for pre‐treatment quality assurance of single target, flattening filter free (FFF), volumetric arc therapy intracranial radiosurgery plans. Methods: A PD algorithm was created for a 10X FFF beam on a Varian Edge linear accelerator (Varian Inc, Palo Alto, CA, USA). Treatment plans that were previously evaluated with Gafchromic EBT‐XD (Ashland, Bridgewater, NJ, USA) film were measured via PD and analyzed with the ARIA Portal Dosimetry workspace. Absolute dose evaluation for film and PD was done by computing the mean dose in the region receiving greater than or equal to 90% of the max dose and comparing to the mean dose in the same region calculated by the treatment planning system (TPS). Gamma analysis with 10% threshold and 3%/2 mm passing criteria was performed on film and portal images. Results: Thirty‐six PD verification plans were delivered and analyzed. The average PD to TPS dose was 0.989 ± 0.01 while film to TPS dose was 1.026 ± 0.01. All PD plans passed the gamma analysis with 100% of points having gamma <1. Overall, PD to TPS dose agreement was found to be target size dependent. As target size decreases, PD to TPS dose ratio decreased from 1.004 for targets with diameters between 15–31 mm and 0.978 for targets with diameters less than 15 mm. Conclusion: The agreement of PD to TPS mean dose in the high dose region was found to be dependent on target size. Film measurements did not exhibit size dependence. All PD plans passed the 3%/2 mm gamma analysis, but caution should be used when using PD to assess overall dosimetric accuracy of the treatment plan for small targets. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 20:Issue 5(2019)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 20:Issue 5(2019)
- Issue Display:
- Volume 20, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 5
- Issue Sort Value:
- 2019-0020-0005-0000
- Page Start:
- 135
- Page End:
- 140
- Publication Date:
- 2019-04-01
- Subjects:
- portal dosimetry -- quality assurance -- stereotactic radiosurgery
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12578 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10406.xml