Sample preparation method for visualization of nanoparticulate captured on mixed cellulose ester filter media by enhanced darkfield microscopy and hyperspectral imaging. Issue 6 (15th February 2019)
- Record Type:
- Journal Article
- Title:
- Sample preparation method for visualization of nanoparticulate captured on mixed cellulose ester filter media by enhanced darkfield microscopy and hyperspectral imaging. Issue 6 (15th February 2019)
- Main Title:
- Sample preparation method for visualization of nanoparticulate captured on mixed cellulose ester filter media by enhanced darkfield microscopy and hyperspectral imaging
- Authors:
- Neu‐Baker, Nicole M.
Eastlake, Adrienne C.
Brenner, Sara A. - Abstract:
- Abstract: A significant hurdle in conducting effective health and safety hazard analysis and risk assessment for the nanotechnology workforce is the lack of a rapid method for the direct visualization and analysis of filter media used to sample nanomaterials from work environments that represent potential worker exposure. Current best‐known methods include transmission electron microscopy (TEM) coupled with energy dispersive x‐ray spectroscopy (EDS) for elemental identification. TEM‐EDS is considerably time‐, cost‐, and resource‐intensive, which may prevent timely health and safety recommendations and corrective actions. A rapid screening method is currently being explored using enhanced darkfield microscopy with hyperspectral imaging (EDFM‐HSI). For this approach to be effective, rapid, and easy, sample preparation that is amenable to the analytical technique is needed. Here, we compare the sample preparation steps for mixed cellulose ester (MCE) filter media specified in NIOSH Method 7400—Asbestos and Other Fibers by Phase Contrast Microscopy (PCM)—against a new method, which involves saturation of the filter media with acetone. NIOSH Method 7400 was chosen as a starting point since it is an established technique for preparing transparent MCE filters for optical microscopy. Limitations in this method led to the development and comparison of a new method. The new method was faster, easier, and rendered filters more transparent, resulting in improved visualization andAbstract: A significant hurdle in conducting effective health and safety hazard analysis and risk assessment for the nanotechnology workforce is the lack of a rapid method for the direct visualization and analysis of filter media used to sample nanomaterials from work environments that represent potential worker exposure. Current best‐known methods include transmission electron microscopy (TEM) coupled with energy dispersive x‐ray spectroscopy (EDS) for elemental identification. TEM‐EDS is considerably time‐, cost‐, and resource‐intensive, which may prevent timely health and safety recommendations and corrective actions. A rapid screening method is currently being explored using enhanced darkfield microscopy with hyperspectral imaging (EDFM‐HSI). For this approach to be effective, rapid, and easy, sample preparation that is amenable to the analytical technique is needed. Here, we compare the sample preparation steps for mixed cellulose ester (MCE) filter media specified in NIOSH Method 7400—Asbestos and Other Fibers by Phase Contrast Microscopy (PCM)—against a new method, which involves saturation of the filter media with acetone. NIOSH Method 7400 was chosen as a starting point since it is an established technique for preparing transparent MCE filters for optical microscopy. Limitations in this method led to the development and comparison of a new method. The new method was faster, easier, and rendered filters more transparent, resulting in improved visualization and analysis of nanomaterials via EDFM‐HSI. This new method is suitable for a rapid screening protocol due to its speed, ease of use, and the improvement in image acquisition and analysis. Abstract : NIOSH Method 7400 was compared to a new method for preparing mixed cellulose ester filters for hyperspectral imaging. The new method of filter saturation with liquid acetone yielded improved imaging data for nanoparticles as compared to Method 7400. … (more)
- Is Part Of:
- Microscopy research and technique. Volume 82:Issue 6(2019)
- Journal:
- Microscopy research and technique
- Issue:
- Volume 82:Issue 6(2019)
- Issue Display:
- Volume 82, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 6
- Issue Sort Value:
- 2019-0082-0006-0000
- Page Start:
- 878
- Page End:
- 883
- Publication Date:
- 2019-02-15
- Subjects:
- acetone vaporization -- engineered nanomaterial -- exposure assessment -- phase contrast microscopy
Electron microscopy -- Technique -- Periodicals
Microscopy -- Periodicals
Microscopy -- Technique -- Periodicals
502.825 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-0029 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jemt.23231 ↗
- Languages:
- English
- ISSNs:
- 1059-910X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5760.600850
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10400.xml