Enhancing the phase distribution in parallel vertical channels with single and double chamber coaxial headers. (5th June 2019)
- Record Type:
- Journal Article
- Title:
- Enhancing the phase distribution in parallel vertical channels with single and double chamber coaxial headers. (5th June 2019)
- Main Title:
- Enhancing the phase distribution in parallel vertical channels with single and double chamber coaxial headers
- Authors:
- Marchitto, Annalisa
Fossa, Marco - Abstract:
- Highlights: Experimental study of air-water phase distribution in parallel vertical channels. Comparison between a series of cylindrical distributors with in-line holes. Best distribution figure of merit for the "double chamber flute" fitting. A new overall performance parameter is used for data reduction. Abstract: In this paper, in order to maximize the degree of flow rate uniformity of the two phase flow distribution into parallel vertical channels, a number of distributor fittings have been tested with respect to a test section characterized by a horizontal header and a series of vertical upward channels. The fluids are air and water and the flow regimes at the header cover the intermittent and annular flow pattern conditions. The ranges of liquid and gas superficial velocities are 0.45–1.2 and 1.5–16.5 m/s, respectively. A header geometry without any inserts, such as the smooth reference header, is taken as a reference case. Data from a number of inserts to enhance the uniformity of distribution are compared to the reference case, such as a series of cylindrical distributors with in-line holes along their length ("flutes"). New data in particular are presented for the "double chamber flute" fitting. As in previous studies by the Authors, extracted mass flow rates of liquid and gas from parallel channels are recast in terms of normalized flow rates and normalized standard deviation of phases. A new overall performance parameter is used for data reduction and forHighlights: Experimental study of air-water phase distribution in parallel vertical channels. Comparison between a series of cylindrical distributors with in-line holes. Best distribution figure of merit for the "double chamber flute" fitting. A new overall performance parameter is used for data reduction. Abstract: In this paper, in order to maximize the degree of flow rate uniformity of the two phase flow distribution into parallel vertical channels, a number of distributor fittings have been tested with respect to a test section characterized by a horizontal header and a series of vertical upward channels. The fluids are air and water and the flow regimes at the header cover the intermittent and annular flow pattern conditions. The ranges of liquid and gas superficial velocities are 0.45–1.2 and 1.5–16.5 m/s, respectively. A header geometry without any inserts, such as the smooth reference header, is taken as a reference case. Data from a number of inserts to enhance the uniformity of distribution are compared to the reference case, such as a series of cylindrical distributors with in-line holes along their length ("flutes"). New data in particular are presented for the "double chamber flute" fitting. As in previous studies by the Authors, extracted mass flow rates of liquid and gas from parallel channels are recast in terms of normalized flow rates and normalized standard deviation of phases. A new overall performance parameter is used for data reduction and for summarizing the comparison between the flute fitting configurations. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 155(2019)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 155(2019)
- Issue Display:
- Volume 155, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 155
- Issue:
- 2019
- Issue Sort Value:
- 2019-0155-2019-0000
- Page Start:
- 239
- Page End:
- 246
- Publication Date:
- 2019-06-05
- Subjects:
- Flow distribution -- Air-water mixture -- Parallel channels -- Plate heat exchangers -- Flute fitting
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2019.03.105 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10389.xml