A portable bioimpedance instrument for monitoring residual limb fluid volume in people with transtibial limb loss: A technical note. (June 2019)
- Record Type:
- Journal Article
- Title:
- A portable bioimpedance instrument for monitoring residual limb fluid volume in people with transtibial limb loss: A technical note. (June 2019)
- Main Title:
- A portable bioimpedance instrument for monitoring residual limb fluid volume in people with transtibial limb loss: A technical note
- Authors:
- Hinrichs, Paul
Cagle, John C.
Sanders, Joan E. - Abstract:
- Abstract : Portable system applied 26 frequency bursts per second between 3 kHz and 1 MHz. Unit was of dimension 15 cm × 11 cm × 4 cm, weighed 3.9 N, and sampled at 30 Hz. Mean RMS errors were 0.07% for Re, 2.23% for Ri, and 1.15% for Cm . Errors at high frequencies were from the voltage controlled current source. Abstract: People with transtibial limb loss experience daily changes in volume of their residual limb that affect the fit of their prosthetic socket. A portable instrument was developed to monitor fluid volume changes outside of the laboratory setting. The bioimpedance system applied 26 current bursts per second at frequencies between 3 kHz and 1 MHz, and sensed voltage at up to six channels. Among six voltage-controlled current source circuits and five receive-channel amplifier topologies considered, a differential Howland current pump and a single receive-channel instrumentation amplifier proved the best combination of low noise and low power consumption. Mean RMS errors were 0.07% for extracellular fluid resistance, 2.23% for intracellular fluid resistance, and 1.15% for membrane capacitance.
- Is Part Of:
- Medical engineering & physics. Volume 68(2019)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 68(2019)
- Issue Display:
- Volume 68, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 68
- Issue:
- 2019
- Issue Sort Value:
- 2019-0068-2019-0000
- Page Start:
- 101
- Page End:
- 107
- Publication Date:
- 2019-06
- Subjects:
- Bioimpedance -- Amputee -- Residual limb -- Fluid volume -- Prosthetic fit -- Volume accommodation
α correction term -- μSD micro SD card -- ρe resistivity of extracellular fluid -- ADC analog to digital converter -- C mean circumference of the residual limb -- Cm membrane capacitance -- CMR common mode signal rejection -- DAC digital to analog converter -- FPGA field-programmable gate array -- I resistive component of bioimpedance -- L distance between voltage-sensing electrodes -- Msps megasamples per second -- Q reactance component of bioimpedance -- Re extracellular fluid resistance -- Ri intracellular fluid resistance -- RMS root mean square -- Td transmission delay term -- USB universal serial bus -- Ve extracellular fluid volume -- VCCS voltage controlled current source -- Zdistal impedance between the distal voltage-sensing and distal current-injecting electrodes -- Zn Impedance in channel n -- Zobs Observed complex impedance -- Zthigh Impedance between the proximal voltage-sensing and proximal current-injecting electrodes
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2019.04.002 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10384.xml