Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth. (14th June 2016)
- Record Type:
- Journal Article
- Title:
- Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth. (14th June 2016)
- Main Title:
- Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth
- Authors:
- Huang, Jinhai
Lu, Weicong
Savini, Giacomo
Chen, Hao
Wang, Chengfang
Yu, Xinxin
Bao, Fangjun
Wang, Qinmei - Other Names:
- Saleh George M. Academic Editor.
- Abstract:
- Abstract : Purpose. To compare between a new optical biometer (AL-Scan, Nidek Co., Aichi, Japan) and an anterior segment optical coherence tomographer (Visante AS-OCT, Carl Zeiss Meditec, Dublin, USA) for measuring central corneal thickness (CCT), anterior chamber depth (ACD), and aqueous depth (AD). Methods. Sixty-three eyes of 63 normal subjects were examined with AL-Scan and Visante AS-OCT in this prospective study. One eye per subject was measured three times with both devices to record their CCT, ACD, and AD. All procedures were performed by the same operator. Agreement between the two devices was assessed using paired t -tests, Bland-Altman plots, and 95% limits of agreement (LoA). Results. The mean CCT, ACD, and AD measured by AL-Scan were538.59 ± 27.37 μ m, 3.70 ± 0.30 mm, and3.16 ± 0.30 mm, respectively. The mean values obtained by the Visante OCT were536.14 ± 26.61 μ m for CCT, 3.71 ± 0.29 mm for ACD, and3.17 ± 0.29 mm for AD. The mean CCT by the AL-Scan was higher than that obtained by the Visante AS-OCT (difference =2.45 ± 6.07 μ m, P < 0.05 ). The differences in ACD and AD measurements were not statistically significant. The 95% LoA of CCT, ACD, and AD were between −9.44 and 14.35 μ m, −0.15 and 0.12 mm, and −0.15 and 0.12 mm, respectively. Conclusions. Since these two devices were comparable for measuring CCT, ACD, and AD, their results can be interchangeably used in the clinic.
- Is Part Of:
- Journal of ophthalmology. Volume 2016(2016)
- Journal:
- Journal of ophthalmology
- Issue:
- Volume 2016(2016)
- Issue Display:
- Volume 2016, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 2016
- Issue:
- 2016
- Issue Sort Value:
- 2016-2016-2016-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-06-14
- Subjects:
- Ophthalmology -- Periodicals
Eye Diseases
Ophthalmology
Ophthalmology
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
Periodicals
617.7 - Journal URLs:
- https://www.hindawi.com/journals/joph/ ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1195/ ↗
http://bibpurl.oclc.org/web/46495 ↗
http://search.ebscohost.com/direct.asp?db=a9h&jid=%229038%22&scope=site ↗ - DOI:
- 10.1155/2016/6347236 ↗
- Languages:
- English
- ISSNs:
- 2090-004X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 10371.xml