Chimney Endovascular Aneurysm Repair Using Endurant Stent-Grafts With Bare Balloon-Expandable Stents for Patients With Juxtarenal Aortic Aneurysms. (June 2019)
- Record Type:
- Journal Article
- Title:
- Chimney Endovascular Aneurysm Repair Using Endurant Stent-Grafts With Bare Balloon-Expandable Stents for Patients With Juxtarenal Aortic Aneurysms. (June 2019)
- Main Title:
- Chimney Endovascular Aneurysm Repair Using Endurant Stent-Grafts With Bare Balloon-Expandable Stents for Patients With Juxtarenal Aortic Aneurysms
- Authors:
- Morikage, Noriyasu
Mizoguchi, Takahiro
Takeuchi, Yuriko
Nagase, Takashi
Samura, Makoto
Ueda, Koshiro
Suehiro, Kotaro
Hamano, Kimikazu - Abstract:
- Purpose: To evaluate the advantages of chimney endovascular aneurysm repair (chEVAR) using an Endurant stent-graft with uncovered balloon-expandable stents (BES) for patients with juxtarenal aortic aneurysms.Materials and Methods: Twenty-two patients (mean age 78.5±9.0 years; 13 men) who underwent chEVAR using Endurant and uncovered BES between January 2014 and December 2017 were analyzed retrospectively. The maximum aneurysm diameter was 59.1±11.9 mm, and the proximal neck length was 5.2±2.9 mm. Of the 22 cases, 9 (40%) involved proximal neck angulation and 9 (40%) had a conical neck. Single and double chimneys were performed using BES in 19 and 3 cases, respectively. In 2 cases, an additional self-expanding covered stent was used inside the uncovered BES.Results: The technical success was 91% (20/22) as 2 (9%) cases showed minor type Ia endoleak. No postoperative systemic complications or acute renal dysfunction (Acute Kidney Injury Network classification stage 2 or higher) were observed. The mean radiologic observation period was 16.1±9.6 months, and no aneurysm expansion (>5 mm) was observed during this time. The mean maximum aneurysm diameter decreased to 52.9±10.2 mm (p<0.001 vs preoperative), with an individual mean sac regression of 6.2±5.9 mm. Overall primary chimney stent patency was 100%. One of the 2 cases of intraoperative type Ia endoleak resolved at the 6-month imaging, and no new type Ia endoleaks developed in any cases at follow-up. No additional treatment-Purpose: To evaluate the advantages of chimney endovascular aneurysm repair (chEVAR) using an Endurant stent-graft with uncovered balloon-expandable stents (BES) for patients with juxtarenal aortic aneurysms.Materials and Methods: Twenty-two patients (mean age 78.5±9.0 years; 13 men) who underwent chEVAR using Endurant and uncovered BES between January 2014 and December 2017 were analyzed retrospectively. The maximum aneurysm diameter was 59.1±11.9 mm, and the proximal neck length was 5.2±2.9 mm. Of the 22 cases, 9 (40%) involved proximal neck angulation and 9 (40%) had a conical neck. Single and double chimneys were performed using BES in 19 and 3 cases, respectively. In 2 cases, an additional self-expanding covered stent was used inside the uncovered BES.Results: The technical success was 91% (20/22) as 2 (9%) cases showed minor type Ia endoleak. No postoperative systemic complications or acute renal dysfunction (Acute Kidney Injury Network classification stage 2 or higher) were observed. The mean radiologic observation period was 16.1±9.6 months, and no aneurysm expansion (>5 mm) was observed during this time. The mean maximum aneurysm diameter decreased to 52.9±10.2 mm (p<0.001 vs preoperative), with an individual mean sac regression of 6.2±5.9 mm. Overall primary chimney stent patency was 100%. One of the 2 cases of intraoperative type Ia endoleak resolved at the 6-month imaging, and no new type Ia endoleaks developed in any cases at follow-up. No additional treatment- or aneurysm-related events were observed.Conclusion: Short-term outcomes of chEVAR using Endurant with uncovered BES have been favorable when covered stents were unavailable, and it can be useful for high-risk patients with juxtarenal aortic aneurysms. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 26:Number 3(2019:Jun.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 26:Number 3(2019:Jun.)
- Issue Display:
- Volume 26, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 26
- Issue:
- 3
- Issue Sort Value:
- 2019-0026-0003-0000
- Page Start:
- 350
- Page End:
- 358
- Publication Date:
- 2019-06
- Subjects:
- abdominal aortic aneurysm -- balloon-expandable stents -- chimney technique -- conical neck -- endoleak -- juxtarenal aortic aneurysm -- proximal neck -- neck angulation -- self-expanding stent-graft
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602819837311 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10354.xml