Conventional Ultra-high Molecular Weight Polyethylene versus Highly Cross-linked Polyethylene from Semi-constrained, Fixed-bearing Total Ankle Arthroplasty Systems: A Comparison of Wear Characteristics. Issue 3 (14th September 2018)
- Record Type:
- Journal Article
- Title:
- Conventional Ultra-high Molecular Weight Polyethylene versus Highly Cross-linked Polyethylene from Semi-constrained, Fixed-bearing Total Ankle Arthroplasty Systems: A Comparison of Wear Characteristics. Issue 3 (14th September 2018)
- Main Title:
- Conventional Ultra-high Molecular Weight Polyethylene versus Highly Cross-linked Polyethylene from Semi-constrained, Fixed-bearing Total Ankle Arthroplasty Systems
- Authors:
- Schipper, Oliver
Haddad, Steven
Fullam, Spencer
Pourzal, Robin
Wimmer, Markus - Abstract:
- Category: Ankle Arthritis Introduction/Purpose: The aim of this study was to compare the polyethylene wear rate, particle size, and particle shape of primary semi-constrained, fixed-bearing, bone-sparing total ankle arthroplasty using conventional ultra-high molecular weight polyethylene (CPE) versus highly cross-linked polyethylene (HXLPE) by applying a level walking input using a joint simulator. Methods: Two fixed-bearing total ankle replacement systems with different types of polyethylene liners were tested: 1.) CPE sterilized in ethylene oxide, and 2.) HXLPE sterilized with gas plasma after electron beam irradiation. Three implants for each design underwent wear testing using gravimetric analysis over 5 million simulated walking cycles. A fourth implant was used as a load soak control. Equivalent circle diameter (ECD) and equivalent shape ratio (ESR) were computed to determine particle size and particle shape, respectively. Results: The mean wear rate from 1.5-5 million cycles (MC) was 2.0±0.3mg/MC for HXLPE and 16.7±1.3mg/MC for CPE (P < 0.001). The total number of particles per cycle generated for HXLPE and CPE were 0.17x106 particles/cycle and 0.53x106 particles/cycle, respectively (P < 0.001). The mean ECD of HXLPE particles (0.22 ±0.11μm) was significantly smaller than the mean ECD of CPE particles (0.32±0.14μm) (P<0.001). HXLPE particles were significantly more round than CPE particles (P<0.001). Conclusion: HXLPE liners had a significantly lower wear rate andCategory: Ankle Arthritis Introduction/Purpose: The aim of this study was to compare the polyethylene wear rate, particle size, and particle shape of primary semi-constrained, fixed-bearing, bone-sparing total ankle arthroplasty using conventional ultra-high molecular weight polyethylene (CPE) versus highly cross-linked polyethylene (HXLPE) by applying a level walking input using a joint simulator. Methods: Two fixed-bearing total ankle replacement systems with different types of polyethylene liners were tested: 1.) CPE sterilized in ethylene oxide, and 2.) HXLPE sterilized with gas plasma after electron beam irradiation. Three implants for each design underwent wear testing using gravimetric analysis over 5 million simulated walking cycles. A fourth implant was used as a load soak control. Equivalent circle diameter (ECD) and equivalent shape ratio (ESR) were computed to determine particle size and particle shape, respectively. Results: The mean wear rate from 1.5-5 million cycles (MC) was 2.0±0.3mg/MC for HXLPE and 16.7±1.3mg/MC for CPE (P < 0.001). The total number of particles per cycle generated for HXLPE and CPE were 0.17x106 particles/cycle and 0.53x106 particles/cycle, respectively (P < 0.001). The mean ECD of HXLPE particles (0.22 ±0.11μm) was significantly smaller than the mean ECD of CPE particles (0.32±0.14μm) (P<0.001). HXLPE particles were significantly more round than CPE particles (P<0.001). Conclusion: HXLPE liners had a significantly lower wear rate and produced significantly fewer and rounder particles than CPE liners. The results of this study suggest that HXLPE has more favorable wear characteristics for total ankle arthroplasty. … (more)
- Is Part Of:
- Foot & ankle orthopaedics. Volume 3:Issue 3(2018)
- Journal:
- Foot & ankle orthopaedics
- Issue:
- Volume 3:Issue 3(2018)
- Issue Display:
- Volume 3, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 3
- Issue:
- 3
- Issue Sort Value:
- 2018-0003-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-09-14
- Subjects:
- polyethylene -- ankle arthroplasty -- ankle replacement -- highly-cross linked polyethylene -- ultra-high molecular weight polyethylene -- fixed-bearing
Foot -- Surgery -- Periodicals
Ankle -- Surgery -- Periodicals
Orthopedics -- Periodicals
617.584 - Journal URLs:
- http://www.sagepublications.com/ ↗
http://journals.sagepub.com/toc/faoa/current ↗ - DOI:
- 10.1177/2473011418S00107 ↗
- Languages:
- English
- ISSNs:
- 2473-0114
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10344.xml