Electrospray ionization-ion mobility spectrometry–high resolution tandem mass spectrometry with collision-induced charge stripping for the analysis of highly multiply charged intact polymers. Issue 10 (23rd April 2019)
- Record Type:
- Journal Article
- Title:
- Electrospray ionization-ion mobility spectrometry–high resolution tandem mass spectrometry with collision-induced charge stripping for the analysis of highly multiply charged intact polymers. Issue 10 (23rd April 2019)
- Main Title:
- Electrospray ionization-ion mobility spectrometry–high resolution tandem mass spectrometry with collision-induced charge stripping for the analysis of highly multiply charged intact polymers
- Authors:
- Ozeki, Yuka
Omae, Mizuki
Kitagawa, Shinya
Ohtani, Hajime - Abstract:
- Abstract : Analysis of highly multiply charged polymers by IMS-MS/MS with collision-induced charge stripping. Abstract : Polymers with large molecular weight are difficult to interpret using electrospray ionization-mass spectrometry (ESI-MS) due to the generation of various highly multiply charged analytes. Although ESI-ion mobility spectrometry (IMS)-MS is effective in reducing the complexity of the mass spectrum, this approach is insufficient for analyzing highly multiply charged polymers. In this study, we propose a method combining tandem mass spectrometry (quadrupole and high-resolution time-of-flight MS, QMS/TOFMS), IMS, and collision-induced charge stripping (CICS) for analyzing large intact polymers (∼40 kDa), which are highly multiply charged. The number of charges can be estimated from a Fourier transform power spectrum of a mass spectrum when the charge number is less than approximately 20. Interpretations of the spectra of poly(ethylene oxide)s (PEOs) weighing 20 kDa, poly(methyl methacrylate)s weighing 22 kDa, and methoxy-PEO-maleimide weighing 40 kDa were successfully demonstrated with isotope level and polymerization degree level separations, respectively. In the proposed method, a mixture can be analyzed for relatively small (a few kDa) and large (a few tens of kDa) polymers simultaneously without any sample pretreatment.
- Is Part Of:
- Analyst. Volume 144:Issue 10(2019)
- Journal:
- Analyst
- Issue:
- Volume 144:Issue 10(2019)
- Issue Display:
- Volume 144, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 144
- Issue:
- 10
- Issue Sort Value:
- 2019-0144-0010-0000
- Page Start:
- 3428
- Page End:
- 3435
- Publication Date:
- 2019-04-23
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8an02500b ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10333.xml