Improving the sensitivity of a multi-collector inductively coupled plasma mass spectrometer via expansion-chamber pressure reduction. Issue 5 (13th February 2019)
- Record Type:
- Journal Article
- Title:
- Improving the sensitivity of a multi-collector inductively coupled plasma mass spectrometer via expansion-chamber pressure reduction. Issue 5 (13th February 2019)
- Main Title:
- Improving the sensitivity of a multi-collector inductively coupled plasma mass spectrometer via expansion-chamber pressure reduction
- Authors:
- Yuan, Honglin
Bao, Zhian
Chen, Kaiyun
Zong, Chunlei
Chen, Lu
Zhang, Tao - Abstract:
- Abstract : In this work, we improved the sensitivity of a MC-ICP-MS by increasing the vacuum of the expansion chamber using a high-speed EH mechanical booster pump in conjunction with a standard E2M80 pump. Abstract : In this work, we improved the sensitivity of a multi-collector-inductively coupled plasma mass spectrometry system by increasing the vacuum of the expansion chamber using a high-speed EH mechanical booster pump (EH500, 500 m 3 h −1, BOC Edwards) in conjunction with a standard E2M80 pump (80 m 3 h −1, BOC Edwards). The vacuum was improved from 1.0 mbar to less than 0.5 mbar. The sample ion yield for heavy isotopes, such as those of Pb, was improved from 0.047% to 0.072% in the wet-plasma mode (sample uptake rate, 113 μL min −1 ), and from 1.35% to 1.84% in the dry-plasma mode (sample uptake rate 105 μL min −1 ); the variation in the background intensity was less than 1.3 mV for all the Faraday cups. Thus, the sample ion yield in the wet-plasma mode was enhanced more effectively than that in the dry-plasma mode owing to a slightly larger orifice in the wet cone setup. The accuracies for all the isotopes tested, including those of non-traditional metal ones, in both modes were identical to previously published data within an error of 2 s. These results indicate that improving the vacuum at the interface has no effect on the accuracy of isotope measurements and is an effective method for improving the detectability of isotopic compositions for bulk solutionAbstract : In this work, we improved the sensitivity of a MC-ICP-MS by increasing the vacuum of the expansion chamber using a high-speed EH mechanical booster pump in conjunction with a standard E2M80 pump. Abstract : In this work, we improved the sensitivity of a multi-collector-inductively coupled plasma mass spectrometry system by increasing the vacuum of the expansion chamber using a high-speed EH mechanical booster pump (EH500, 500 m 3 h −1, BOC Edwards) in conjunction with a standard E2M80 pump (80 m 3 h −1, BOC Edwards). The vacuum was improved from 1.0 mbar to less than 0.5 mbar. The sample ion yield for heavy isotopes, such as those of Pb, was improved from 0.047% to 0.072% in the wet-plasma mode (sample uptake rate, 113 μL min −1 ), and from 1.35% to 1.84% in the dry-plasma mode (sample uptake rate 105 μL min −1 ); the variation in the background intensity was less than 1.3 mV for all the Faraday cups. Thus, the sample ion yield in the wet-plasma mode was enhanced more effectively than that in the dry-plasma mode owing to a slightly larger orifice in the wet cone setup. The accuracies for all the isotopes tested, including those of non-traditional metal ones, in both modes were identical to previously published data within an error of 2 s. These results indicate that improving the vacuum at the interface has no effect on the accuracy of isotope measurements and is an effective method for improving the detectability of isotopic compositions for bulk solution analysis with low element contents and the spatial resolution for measurements performed using the laser-ablation sampling technique. This work could provide an alternative for laboratories with a similar device, when tackling samples with low contents. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 34:Issue 5(2019)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 34:Issue 5(2019)
- Issue Display:
- Volume 34, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 34
- Issue:
- 5
- Issue Sort Value:
- 2019-0034-0005-0000
- Page Start:
- 1011
- Page End:
- 1017
- Publication Date:
- 2019-02-13
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8ja00448j ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10333.xml