Extensive sensitivity analysis of Implantable Cardioverter Defibrillators by an Automatic Sensing Test procedure. (February 2019)
- Record Type:
- Journal Article
- Title:
- Extensive sensitivity analysis of Implantable Cardioverter Defibrillators by an Automatic Sensing Test procedure. (February 2019)
- Main Title:
- Extensive sensitivity analysis of Implantable Cardioverter Defibrillators by an Automatic Sensing Test procedure
- Authors:
- Lai, Andrea
Serpi, Alessandro
Sulis, Sara
Gatto, Gianluca - Abstract:
- Highlights: Sensing of Implantable Cardioverter Defibrillator (ICD) is a critical issue. The Sensitivity Test for ICDs provided by international standards is described. A novel Automatic Sensing Test procedure (AST) is presented. An extensive experimental characterization of the AST is carried out. The results prove the usefulness of the proposed AST compared to Sensitivity Test. Abstract: An Automatic Sensing Test methodology, in the following indicated as AST, is presented in this paper. The AST permits an extensive sensitivity analysis of implantable cardiac medical devices, among which Implantable Cardioverter Defibrillator (ICD). The AST is designed to evaluate the thresholds of the ICD sensing, considering different heart rates. In this way, it is possible to take into account different patient's states of health. Consequently, it is possible to obtain a comprehensive assessment of ICD sensing performance. The AST is fielded through an optimized automatic measurement system implemented by means of an accurate general-purpose hardware platform. The procedure is based on dedicated virtual instruments. The developed environment is LabVIEW, by the National Instruments. The characterization process is based on an extensive experimental validation and field testing, which have been carried out by employing different ICD sensitivity settings and in two different scenarios: a 3-meter-high semi anechoic Radio Frequency Chamber, which is suited for electromagnetic pre-complianceHighlights: Sensing of Implantable Cardioverter Defibrillator (ICD) is a critical issue. The Sensitivity Test for ICDs provided by international standards is described. A novel Automatic Sensing Test procedure (AST) is presented. An extensive experimental characterization of the AST is carried out. The results prove the usefulness of the proposed AST compared to Sensitivity Test. Abstract: An Automatic Sensing Test methodology, in the following indicated as AST, is presented in this paper. The AST permits an extensive sensitivity analysis of implantable cardiac medical devices, among which Implantable Cardioverter Defibrillator (ICD). The AST is designed to evaluate the thresholds of the ICD sensing, considering different heart rates. In this way, it is possible to take into account different patient's states of health. Consequently, it is possible to obtain a comprehensive assessment of ICD sensing performance. The AST is fielded through an optimized automatic measurement system implemented by means of an accurate general-purpose hardware platform. The procedure is based on dedicated virtual instruments. The developed environment is LabVIEW, by the National Instruments. The characterization process is based on an extensive experimental validation and field testing, which have been carried out by employing different ICD sensitivity settings and in two different scenarios: a 3-meter-high semi anechoic Radio Frequency Chamber, which is suited for electromagnetic pre-compliance test due to proper shielding against external electromagnetic noise, and an unshielded environment, which is more common for ICD operation. Detailed results are shown and discussed. They prove the validity of the proposed AST in both environments, in terms of a more extensive ICD characterization than that achievable by the Sensitivity Test described in the international standards, which is the starting point of the proposed procedure. … (more)
- Is Part Of:
- Measurement. Volume 134(2019)
- Journal:
- Measurement
- Issue:
- Volume 134(2019)
- Issue Display:
- Volume 134, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 134
- Issue:
- 2019
- Issue Sort Value:
- 2019-0134-2019-0000
- Page Start:
- 930
- Page End:
- 938
- Publication Date:
- 2019-02
- Subjects:
- Automatic testing -- Implantable biomedical devices -- Sensitivity -- Sensitivity analysis -- Testing
Weights and measures -- Periodicals
Measurement -- Periodicals
Measurement
Weights and measures
Periodicals
530.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02632241 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.measurement.2018.12.048 ↗
- Languages:
- English
- ISSNs:
- 0263-2241
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5413.544700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10330.xml