Application and reliability of the superselective balloon occlusion test in the treatment of complex cerebral artery aneurysms: A report of 12 cases. (June 2019)
- Record Type:
- Journal Article
- Title:
- Application and reliability of the superselective balloon occlusion test in the treatment of complex cerebral artery aneurysms: A report of 12 cases. (June 2019)
- Main Title:
- Application and reliability of the superselective balloon occlusion test in the treatment of complex cerebral artery aneurysms: A report of 12 cases
- Authors:
- Ma, Yudong
Zhang, Yan
Jiang, Jingli
Li, Sheng
Ni, Taoyi
Liu, Lei
Xue, Zhe
Wu, Chen
Sun, Zhenghui
Yu, Xinguang - Abstract:
- Highlights: Linical tolerance and vascular reserve should be assessed before performing PAS. Superselective BOT is useful for predicting cerebrovascular tolerance. The right method of occlusion can be chosen based on BOT results. Abstract: Although the general balloon occlusion test (BOT) is commonly used, there is limited information on the evaluation standards and methodological protocols for the superselective BOT, which may be required in some special aneurysm cases. We performed the superselective BOT in 12 patients with specific complex aneurysms and report our experiences herein. We retrospectively analyzed the angiographic results and test outcomes of 12 patients (8 men and 4 women) who underwent the superselective BOT to evaluate their collateral flow before treatment. Eight patients had middle cerebral artery complex aneurysms; 2 patients had carotid-ophthalmic aneurysms; and 2 patients had posterior cerebral artery aneurysms. Collaterals were categorized as none (grade 0), poor (grades 1 or 2), or good (grades 3 or 4) based on the collateral flow grade on angiography. The test results were negative in 10 patients and positive in 2 patients. The delay time of the cortical capillary phase after temporary occlusion of the parent artery was between 0.5 and 2.5 s. The collateral flow was graded as poor in 3 patients and good in 9 patients. There were no technical complications related to the superselective BOT. The superselective BOT can be applied for the evaluationHighlights: Linical tolerance and vascular reserve should be assessed before performing PAS. Superselective BOT is useful for predicting cerebrovascular tolerance. The right method of occlusion can be chosen based on BOT results. Abstract: Although the general balloon occlusion test (BOT) is commonly used, there is limited information on the evaluation standards and methodological protocols for the superselective BOT, which may be required in some special aneurysm cases. We performed the superselective BOT in 12 patients with specific complex aneurysms and report our experiences herein. We retrospectively analyzed the angiographic results and test outcomes of 12 patients (8 men and 4 women) who underwent the superselective BOT to evaluate their collateral flow before treatment. Eight patients had middle cerebral artery complex aneurysms; 2 patients had carotid-ophthalmic aneurysms; and 2 patients had posterior cerebral artery aneurysms. Collaterals were categorized as none (grade 0), poor (grades 1 or 2), or good (grades 3 or 4) based on the collateral flow grade on angiography. The test results were negative in 10 patients and positive in 2 patients. The delay time of the cortical capillary phase after temporary occlusion of the parent artery was between 0.5 and 2.5 s. The collateral flow was graded as poor in 3 patients and good in 9 patients. There were no technical complications related to the superselective BOT. The superselective BOT can be applied for the evaluation of some complex aneurysms prior to treatment. The right method of occlusion can be selected on the basis of the results of this test. … (more)
- Is Part Of:
- Journal of clinical neuroscience. Volume 64(2019)
- Journal:
- Journal of clinical neuroscience
- Issue:
- Volume 64(2019)
- Issue Display:
- Volume 64, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 64
- Issue:
- 2019
- Issue Sort Value:
- 2019-0064-2019-0000
- Page Start:
- 57
- Page End:
- 63
- Publication Date:
- 2019-06
- Subjects:
- Complex aneurysm -- Parent artery sacrifice -- Superselective BOT
Brain -- Surgery -- Periodicals
Neurosciences -- Periodicals
Nervous system -- Surgery -- Periodicals
Brain -- surgery -- Periodicals
Neurosurgical Procedures -- Periodicals
Neurosciences -- Periodicals
Electronic journals
616.8 - Journal URLs:
- http://www.harcourt-international.com/journals ↗
http://www.sciencedirect.com/science/journal/09675868 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09675868 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jocn.2019.04.016 ↗
- Languages:
- English
- ISSNs:
- 0967-5868
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.585000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10328.xml