Subacute Drug-Eluting Stent Thrombosis Caused by Stent Underexpansion: Evaluation by Optical Coherence Tomography. (10th February 2011)
- Record Type:
- Journal Article
- Title:
- Subacute Drug-Eluting Stent Thrombosis Caused by Stent Underexpansion: Evaluation by Optical Coherence Tomography. (10th February 2011)
- Main Title:
- Subacute Drug-Eluting Stent Thrombosis Caused by Stent Underexpansion: Evaluation by Optical Coherence Tomography
- Authors:
- Martín-Reyes, Roberto
Jiménez-Valero, Santiago
Navarro, Felipe
Moreno, Raúl - Other Names:
- Brady William J. Academic Editor.
- Abstract:
- Abstract : We present the case report of a patient presenting with ST segment elevation myocardial infarction due to a subacute drug-eluting stent trombosis within the proximal segment of the left circumflex artery (LCX). Six days before a total chronic occlusion was treated at the mid segment of the LCX by overlapping two drug-eluting stents. Optical coherence tomography (OCT) was helpful to demonstrate stent underexpansion of the overlaping segment as the main mechanism of early stent thrombosis. This case is illustrative about the potential role of OCT to identify the mechanisms of ST and thus guiding the PCI procedure. Moreover, our case shows the capability of the Imagewire to cross a severe stenosis due to stent underexpansion that could not be crossed by the IVUS catheter.
- Is Part Of:
- Case reports in medicine. Volume 2011(2011)
- Journal:
- Case reports in medicine
- Issue:
- Volume 2011(2011)
- Issue Display:
- Volume 2011, Issue 2011 (2011)
- Year:
- 2011
- Volume:
- 2011
- Issue:
- 2011
- Issue Sort Value:
- 2011-2011-2011-0000
- Page Start:
- Page End:
- Publication Date:
- 2011-02-10
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Medicine
Case Reports
Periodicals
610 - Journal URLs:
- http://www.hindawi.com/journals/crm ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/945/ ↗ - DOI:
- 10.1155/2011/129341 ↗
- Languages:
- English
- ISSNs:
- 1687-9627
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 10293.xml