Cold Pulsatile Machine Perfusion versus Static Cold Storage in Kidney Transplantation: A Single Centre Experience. (16th January 2019)
- Record Type:
- Journal Article
- Title:
- Cold Pulsatile Machine Perfusion versus Static Cold Storage in Kidney Transplantation: A Single Centre Experience. (16th January 2019)
- Main Title:
- Cold Pulsatile Machine Perfusion versus Static Cold Storage in Kidney Transplantation: A Single Centre Experience
- Authors:
- Bellini, Maria Irene
Charalampidis, Sotiris
Herbert, Paul Elliot
Bonatsos, Vasileios
Crane, Jeremy
Muthusamy, Anand
Dor, Frank J. M. F.
Papalois, Vassilios - Other Names:
- Stangou Maria Academic Editor.
- Abstract:
- Abstract : Introduction . We present our experience with hypothermic machine perfusion (HMP) versus cold storage (CS) in relation to kidney transplant outcomes. Methods . Retrospective analysis of 33 consecutive HMP kidney transplant outcomes matched with those of 33 cold stored: delayed graft function (DGF), length of hospital stay (LOS), estimated glomerular filtration rate (eGFR), and patient and graft survival were compared. Renal Resistive Indexes (RIs) during HMP in relation to DGF were also analysed. Results . In the HMP group, mean HMP time was 5.7 ± 3.9 hours with a mean cold ischaemic time (CIT) of 15 ± 5.6 versus 15.1 ± 5.3 hours in the CS group. DGF was lower in the HMP group (p=0.041), and donation after Circulatory Death (DCD) was a predictor for DGF (p<0.01). HMP decreased DGF in DCD grafts (p=0.036). Patient and graft survival were similar, but eGFR at 365 days was higher in the HMP cohort (p<0.001). RIs decreased during HMP (p<0.01); 2-hours RI ≥ 0.45 mmHg/mL/min predicted DGF in DCD kidneys (75% sensitivity, 80% specificity; area under the curve 0.78); 2-hours RI ≥ 0.2 mmHg/ml/min predicted DGF in DBD grafts (sensitivity 100%, specificity 91%; area under the curve 0.87). Conclusion . HMP decreased DGF compared to CS, offering viability assessment pretransplant and improving one-year renal function of the grafts.
- Is Part Of:
- BioMed research international. Volume 2019(2019)
- Journal:
- BioMed research international
- Issue:
- Volume 2019(2019)
- Issue Display:
- Volume 2019, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 2019
- Issue:
- 2019
- Issue Sort Value:
- 2019-2019-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-01-16
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2019/7435248 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 10293.xml