Lean Body Weight-Tailored Iodinated Contrast Injection in Obese Patient: Boer versus James Formula. (13th August 2018)
- Record Type:
- Journal Article
- Title:
- Lean Body Weight-Tailored Iodinated Contrast Injection in Obese Patient: Boer versus James Formula. (13th August 2018)
- Main Title:
- Lean Body Weight-Tailored Iodinated Contrast Injection in Obese Patient: Boer versus James Formula
- Authors:
- Caruso, Damiano
De Santis, Domenico
Rivosecchi, Flaminia
Zerunian, Marta
Panvini, Nicola
Montesano, Marta
Biondi, Tommaso
Bellini, Davide
Rengo, Marco
Laghi, Andrea - Other Names:
- Pontone Gianluca Academic Editor.
- Abstract:
- Abstract : Purpose . To prospectively compare the performance of James and Boer formula in contrast media (CM) administration, in terms of image quality and parenchymal enhancement in obese patients undergoing CT of the abdomen. Materials and Methods . Fifty-five patients with a body mass index (BMI) greater than 35 kg/m 2 were prospectively included in the study. All patients underwent 64-row CT examination and were randomly divided in two groups: 26 patients in Group A and 29 patients in Group B. The amount of injected CM was computed according to the patient's lean body weight (LBW), estimated using either Boer formula (Group A) or James formula (Group B). Patient's characteristics, CM volume, contrast-to-noise ratio (CNR) of liver, aorta and portal vein, and liver contrast enhancement index (CEI) were compared between the two groups. For subjective image analysis readers were asked to rate the enhancement of liver, kidneys, and pancreas based on a 5-point Likert scale. Results . Liver CNR, aortic CNR, and portal vein CNR showed no significant difference between Group A and Group B (allP ≥ 0.177 ). Group A provided significantly higher CEI compared to Group B (P = 0.007 ). Group A and Group B returned comparable overall subjective enhancement values (3.54 and vs 3.20, allP ≥ 0.199 ). Conclusions . Boer formula should be the method of choice for LBW estimation in obese patients, leading to an accurate CM amount calculation and an optimal liver contrast enhancement in CT.
- Is Part Of:
- BioMed research international. Volume 2018(2018)
- Journal:
- BioMed research international
- Issue:
- Volume 2018(2018)
- Issue Display:
- Volume 2018, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 2018
- Issue:
- 2018
- Issue Sort Value:
- 2018-2018-2018-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08-13
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2018/8521893 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 10263.xml