Left ventricular diastolic function is strongly correlated with active emptying of the left atrium: a novel analysis using three-dimensional echocardiography. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Left ventricular diastolic function is strongly correlated with active emptying of the left atrium: a novel analysis using three-dimensional echocardiography. Issue 1 (December 2015)
- Main Title:
- Left ventricular diastolic function is strongly correlated with active emptying of the left atrium: a novel analysis using three-dimensional echocardiography
- Authors:
- Scherr, Johannes
Jung, Philip
Schuster, Tibor
Pollmer, Lars
Eisele, Gert
Goss, Franz
Schneider, Jens
Halle, Martin - Abstract:
- Abstract Background Increased left atrial (LA) dimensions are known to be a risk factor in predicting cardiovascular events and mortality and to be one key diagnostic tool to assess diastolic dysfunction. Currently, LA measurements are usually conducted using 2D-echocardiography, although there are well-known limitations. Real-time 3D-echocardiography is able to overcome these limitations, furthermore being a valid measurement tool compared to reference standards (e.g. cardiac magnetic resonance imaging). We investigated LA function and volume and their association to left ventricular (LV) diastolic function, using newly designed and validated software for 3D-echocardiographic analysis. This software is the first to allow for a sophisticated analysis of both passive and active LA emptying. Methods We analyzed 2D- and 3D-echocardiographic measurements of LA volume and function in 56 subjects and compared the results between patients with normal LV diastolic function (NDF) (n = 30, 52 ± 15 years, BMI 24.7 ± 2.6 kg/m2 ) and patients in which diastolic dysfunction (DDF) was suspected (n = 26, 65 ± 9 years, BMI 26.7 ± 3.7 kg/m2 ). Results Volumes during LA active emptying were significantly smaller in DDF compared to NDF (active atrial stroke volume (ASV): 3.0 (0.1–4.5) vs. 5.5 (2.7–7.8) ml, p = 0.005; True-EF: 7.3(0.1–11.5) vs. 16.2 (8.1–25.4) %, p = 0.002). Furthermore, ASV showed a stronger association to E/e'mean than all other measured LA volumes (β = − 0.35, pAbstract Background Increased left atrial (LA) dimensions are known to be a risk factor in predicting cardiovascular events and mortality and to be one key diagnostic tool to assess diastolic dysfunction. Currently, LA measurements are usually conducted using 2D-echocardiography, although there are well-known limitations. Real-time 3D-echocardiography is able to overcome these limitations, furthermore being a valid measurement tool compared to reference standards (e.g. cardiac magnetic resonance imaging). We investigated LA function and volume and their association to left ventricular (LV) diastolic function, using newly designed and validated software for 3D-echocardiographic analysis. This software is the first to allow for a sophisticated analysis of both passive and active LA emptying. Methods We analyzed 2D- and 3D-echocardiographic measurements of LA volume and function in 56 subjects and compared the results between patients with normal LV diastolic function (NDF) (n = 30, 52 ± 15 years, BMI 24.7 ± 2.6 kg/m2 ) and patients in which diastolic dysfunction (DDF) was suspected (n = 26, 65 ± 9 years, BMI 26.7 ± 3.7 kg/m2 ). Results Volumes during LA active emptying were significantly smaller in DDF compared to NDF (active atrial stroke volume (ASV): 3.0 (0.1–4.5) vs. 5.5 (2.7–7.8) ml, p = 0.005; True-EF: 7.3(0.1–11.5) vs. 16.2 (8.1–25.4) %, p = 0.002). Furthermore, ASV showed a stronger association to E/e'mean than all other measured LA volumes (β = − 0.35, p = 0.008). Neither total stroke LA volume, nor maximum or minimum LA volume differed significantly between the groups. Conclusions Diastolic LV dysfunction results in a reduction in active LA emptying, which is more strongly associated with LV filling pressure than other previously investigated LA parameters. … (more)
- Is Part Of:
- Cardiovascular ultrasound. Volume 14:Issue 1(2016)
- Journal:
- Cardiovascular ultrasound
- Issue:
- Volume 14:Issue 1(2016)
- Issue Display:
- Volume 14, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 14
- Issue:
- 1
- Issue Sort Value:
- 2016-0014-0001-0000
- Page Start:
- 1
- Page End:
- 10
- Publication Date:
- 2015-12
- Subjects:
- Three-dimensional echocardiography -- Left atrium -- Left ventricular diastolic function
Echocardiography -- Periodicals
Intravascular ultrasonography -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1207543 - Journal URLs:
- http://www.cardiovascularultrasound.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=195 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12947-016-0085-0 ↗
- Languages:
- English
- ISSNs:
- 1476-7120
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10236.xml