Reproducibility of a novel echocardiographic 3D automated software for the assessment of mitral valve anatomy. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Reproducibility of a novel echocardiographic 3D automated software for the assessment of mitral valve anatomy. Issue 1 (December 2015)
- Main Title:
- Reproducibility of a novel echocardiographic 3D automated software for the assessment of mitral valve anatomy
- Authors:
- Aquila, Iolanda
González, Ariana
Fernández-Golfín, Covadonga
Rincón, Luis
Casas, Eduardo
García, Ana
Hinojar, Rocio
Jiménez-Nacher, José
Zamorano, José - Abstract:
- Abstract Background 3D transesophageal echocardiography (TEE) is superior to 2D TEE in quantitative anatomic evaluation of the mitral valve (MV) but it shows limitations regarding automatic quantification. Here, we tested the inter-/intra-observer reproducibility of a novel full-automated software in the evaluation of MV anatomy compared to manual 3D assessment. Methods Thirty-six out of 61 screened patients referred to our Cardiac Imaging Unit for TEE were retrospectively included. 3D TEE analysis was performed both manually and with the automated software by two independent operators. Mitral annular area, intercommissural distance, anterior leaflet length and posterior leaflet length were assessed. Results A significant correlation between both methods was found for all variables: intercommissural diameter (r = 0.84, p < 0.01), mitral annular area (r = 0.94, p > 0, 01), anterior leaflet length (r = 0.83, p < 0.01) and posterior leaflet length (r = 0.67, p < 0.01). Interobserver variability assessed by the intraclass correlation coefficient was superior for the automatic software: intercommisural distance 0.997 vs. 0.76; mitral annular area 0.957 vs. 0.858; anterior leaflet length 0.963 vs. 0.734 and posterior leaflet length 0.936 vs. 0.838. Intraobserver variability was good for both methods with a better level of agreement with the automatic software. Conclusions The novel 3D automated software is reproducible in MV anatomy assessment. The incorporation of thisAbstract Background 3D transesophageal echocardiography (TEE) is superior to 2D TEE in quantitative anatomic evaluation of the mitral valve (MV) but it shows limitations regarding automatic quantification. Here, we tested the inter-/intra-observer reproducibility of a novel full-automated software in the evaluation of MV anatomy compared to manual 3D assessment. Methods Thirty-six out of 61 screened patients referred to our Cardiac Imaging Unit for TEE were retrospectively included. 3D TEE analysis was performed both manually and with the automated software by two independent operators. Mitral annular area, intercommissural distance, anterior leaflet length and posterior leaflet length were assessed. Results A significant correlation between both methods was found for all variables: intercommissural diameter (r = 0.84, p < 0.01), mitral annular area (r = 0.94, p > 0, 01), anterior leaflet length (r = 0.83, p < 0.01) and posterior leaflet length (r = 0.67, p < 0.01). Interobserver variability assessed by the intraclass correlation coefficient was superior for the automatic software: intercommisural distance 0.997 vs. 0.76; mitral annular area 0.957 vs. 0.858; anterior leaflet length 0.963 vs. 0.734 and posterior leaflet length 0.936 vs. 0.838. Intraobserver variability was good for both methods with a better level of agreement with the automatic software. Conclusions The novel 3D automated software is reproducible in MV anatomy assessment. The incorporation of this new tool in clinical MV assessment may improve patient selection and outcomes for MV interventions as well as patient diagnosis and prognosis stratification. Yet, high-quality 3D images are indispensable. … (more)
- Is Part Of:
- Cardiovascular ultrasound. Volume 14:Issue 1(2016)
- Journal:
- Cardiovascular ultrasound
- Issue:
- Volume 14:Issue 1(2016)
- Issue Display:
- Volume 14, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 14
- Issue:
- 1
- Issue Sort Value:
- 2016-0014-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2015-12
- Subjects:
- Mitral valve -- 3D echocardiography -- Automatic software
Echocardiography -- Periodicals
Intravascular ultrasonography -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1207543 - Journal URLs:
- http://www.cardiovascularultrasound.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=195 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12947-016-0061-8 ↗
- Languages:
- English
- ISSNs:
- 1476-7120
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10236.xml