Intra‐rater Reliability of Arm and Hand Muscle Strength Measurements in Persons With Late Effects of Polio. Issue 10 (25th March 2015)
- Record Type:
- Journal Article
- Title:
- Intra‐rater Reliability of Arm and Hand Muscle Strength Measurements in Persons With Late Effects of Polio. Issue 10 (25th March 2015)
- Main Title:
- Intra‐rater Reliability of Arm and Hand Muscle Strength Measurements in Persons With Late Effects of Polio
- Authors:
- Brogårdh, Christina
Flansbjer, Ulla‐Britt
Carlsson, Håkan
Lexell, Jan - Abstract:
- Abstract: Background: Muscle weakness in the upper limb is common in persons with late effects of polio. To be able to measure muscle strength and follow changes over time, reliable measurements are needed. Objective: To evaluate the intra‐rater reliability of isometric and isokinetic arm and hand muscle strength measurements in persons with late effects of polio. Design: A test‐retest design. Settings: A university hospital outpatient clinic. Participants: Twenty‐eight persons (mean age 68 years, SD 11 years) with late effects of polio in their upper limbs. Methods: Isometric shoulder abduction, isokinetic concentric elbow flexion and extension, isometric elbow flexion, and isometric grip strength were measured twice, 14 days apart. Reliability was evaluated with the intra‐class correlation coefficient, the mean difference between the test sessions ( d ¯ ), together with the 95% confidence intervals for d ¯, the standard error of measurement (SEM and SEM%), the smallest real difference (SRD and SRD%), and Bland‐Altman graphs. Main Outcome Measurements: A fixed dynamometer (Biodex) was used to measure arm strength and an electronic dynamometer (GRIP‐it) was used to measure grip strength. Results: Intra‐rater reliability was high, with intra‐class correlation coefficients between 0.87 and 0.98. The SEM%, representing the smallest change for a group of persons, ranged from 7%‐24% for all strength measurements, and the SRD%, representing the smallest change for an individualAbstract: Background: Muscle weakness in the upper limb is common in persons with late effects of polio. To be able to measure muscle strength and follow changes over time, reliable measurements are needed. Objective: To evaluate the intra‐rater reliability of isometric and isokinetic arm and hand muscle strength measurements in persons with late effects of polio. Design: A test‐retest design. Settings: A university hospital outpatient clinic. Participants: Twenty‐eight persons (mean age 68 years, SD 11 years) with late effects of polio in their upper limbs. Methods: Isometric shoulder abduction, isokinetic concentric elbow flexion and extension, isometric elbow flexion, and isometric grip strength were measured twice, 14 days apart. Reliability was evaluated with the intra‐class correlation coefficient, the mean difference between the test sessions ( d ¯ ), together with the 95% confidence intervals for d ¯, the standard error of measurement (SEM and SEM%), the smallest real difference (SRD and SRD%), and Bland‐Altman graphs. Main Outcome Measurements: A fixed dynamometer (Biodex) was used to measure arm strength and an electronic dynamometer (GRIP‐it) was used to measure grip strength. Results: Intra‐rater reliability was high, with intra‐class correlation coefficients between 0.87 and 0.98. The SEM%, representing the smallest change for a group of persons, ranged from 7%‐24% for all strength measurements, and the SRD%, representing the smallest change for an individual person, ranged from 20%‐67%. Conclusion: Muscle strength in the upper limbs can be reliably measured in persons with late effects of polio. However, the measurement errors indicate that the method is more suitable to detect changes in muscle strength for a group of persons than for an individual person. … (more)
- Is Part Of:
- PM&R. Volume 7:Issue 10(2015)
- Journal:
- PM&R
- Issue:
- Volume 7:Issue 10(2015)
- Issue Display:
- Volume 7, Issue 10 (2015)
- Year:
- 2015
- Volume:
- 7
- Issue:
- 10
- Issue Sort Value:
- 2015-0007-0010-0000
- Page Start:
- 1035
- Page End:
- 1041
- Publication Date:
- 2015-03-25
- Subjects:
- Medical rehabilitation -- Periodicals
Physical therapy -- Periodicals
Physical Therapy Modalities -- Periodicals
615.5 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/19341563 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.pmrj.2015.03.016 ↗
- Languages:
- English
- ISSNs:
- 1934-1482
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6541.077150
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10223.xml