Cherenkov emission‐based external radiotherapy dosimetry: II. Electron beam quality specification and uncertainties. Issue 5 (29th April 2019)
- Record Type:
- Journal Article
- Title:
- Cherenkov emission‐based external radiotherapy dosimetry: II. Electron beam quality specification and uncertainties. Issue 5 (29th April 2019)
- Main Title:
- Cherenkov emission‐based external radiotherapy dosimetry: II. Electron beam quality specification and uncertainties
- Authors:
- Zlateva, Yana
Muir, Bryan R.
Seuntjens, Jan P.
El Naqa, Issam - Abstract:
- Abstract : Purpose: Cherenkov emission (CE) is ubiquitous in external radiotherapy. It is also unique in that it carries the promise of 3D, micrometer‐resolution, perturbation‐free, in‐water dosimetry with a beam quality‐independent detector response calibration. Our aim is to bring CE‐based dosimetry into the clinic and we motivate this here with electron beams. We Monte Carlo (MC) calculate and characterize broad‐beam CE‐to‐dose conversion factors in water for a clinically representative library of electron beam qualities, address beam quality specification and reference depth selection, and develop a preliminary uncertainty budget based on our MC results and relative experimental work of a companion study (Paper I). Methods: Broad electron beam CE‐to‐dose conversion factors k C θ ± δ θ include CE generated at polar angles θ ± δ θ on beam axis in water. With modifications to the EGSnrc code SPRRZnrc, k C θ ± δ θ factors are calculated for a total of 20 electron beam qualities from four BEAMnrc models (Varian Clinac 2100C/D, Clinac 21EX, TrueBeam, and Elekta Precise). We examine beam quality, depth, and detection angle dependence for θ ± δ θ = 90 ∘ ± 90 ∘ (4π detection), 90 ∘ ± 5 ∘, 45 ∘ ± 45 ∘, and 90 ∘ ± 45 ∘ . As discussed in Paper I, 4π detection offers the strongest CE‐dose correlation and θ = 90 ∘ with small δ θ is most practical. The two additional configurations are considered as a compromise between these two extremes. We address beam quality specification andAbstract : Purpose: Cherenkov emission (CE) is ubiquitous in external radiotherapy. It is also unique in that it carries the promise of 3D, micrometer‐resolution, perturbation‐free, in‐water dosimetry with a beam quality‐independent detector response calibration. Our aim is to bring CE‐based dosimetry into the clinic and we motivate this here with electron beams. We Monte Carlo (MC) calculate and characterize broad‐beam CE‐to‐dose conversion factors in water for a clinically representative library of electron beam qualities, address beam quality specification and reference depth selection, and develop a preliminary uncertainty budget based on our MC results and relative experimental work of a companion study (Paper I). Methods: Broad electron beam CE‐to‐dose conversion factors k C θ ± δ θ include CE generated at polar angles θ ± δ θ on beam axis in water. With modifications to the EGSnrc code SPRRZnrc, k C θ ± δ θ factors are calculated for a total of 20 electron beam qualities from four BEAMnrc models (Varian Clinac 2100C/D, Clinac 21EX, TrueBeam, and Elekta Precise). We examine beam quality, depth, and detection angle dependence for θ ± δ θ = 90 ∘ ± 90 ∘ (4π detection), 90 ∘ ± 5 ∘, 45 ∘ ± 45 ∘, and 90 ∘ ± 45 ∘ . As discussed in Paper I, 4π detection offers the strongest CE‐dose correlation and θ = 90 ∘ with small δ θ is most practical. The two additional configurations are considered as a compromise between these two extremes. We address beam quality specification and reference depth selection in terms of the electron beam quality specifier R 50, obtained from the depth of 50% CE C 50, and derive a best‐case uncertainty budget for the CE‐based dosimetry formalism proposed in Paper I at each detection configuration. Results: The k C θ ± δ θ factor was demonstrated to capture variations in the beam spectrum, angle, photon contamination, and electron fluence below the CE threshold (∼260 keV in the visible) in accordance with theory. The root‐mean‐square deviation and maximum deviation of a second‐order polynomial fit of simulated R 50 values in terms of C 50 were 0.05 and 0.11 mm at 4π and 0.20 and 0.33 mm at 90 ∘ ± 5 ∘ detection, respectively. The fit performance on experimental data in Paper I was in agreement with these values within experimental uncertainties (±1.5 mm, 95% CI). A two‐term power function fit of k C θ ± δ θ in terms of R 50 at a reference depth d ref = a R 50 + b resulted in total d ref ‐dependent dose uncertainty contribution estimate of 0.8% and 1.1% and preliminary best‐case estimate of the combined standard dose uncertainty of 1.1% and 1.3% at 4π and 90 ∘ ± 5 ∘ detection, respectively. The results and corresponding uncertainties with the two intermediate apertures were generally of the same order as the 4π case. In addition, a theoretically consistent downstream shift of the percent‐depth CE (PDC) by the difference between R 50 and C 50 improved the depth dependence of the 4π conversion by an order of magnitude (±2.8%). Therefore, a large aperture centered on a θ value between 45 ∘ and 90 ∘ combined with a downstream PDC shift may be recommended for beam‐axis CE‐based electron beam dosimetry in water. Conclusions: By delivering R 50 ‐based CE‐to‐dose conversion data and demonstrating the potential for dosimetric uncertainty on the order of 1%, we bring CE‐based electron beam dosimetry closer to clinical realization. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 5(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 5(2019)
- Issue Display:
- Volume 46, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 5
- Issue Sort Value:
- 2019-0046-0005-0000
- Page Start:
- 2383
- Page End:
- 2393
- Publication Date:
- 2019-04-29
- Subjects:
- Cerenkov -- Cherenkov -- conversion factor -- dosimetry -- electron beam quality -- uncertainty budget
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13413 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10206.xml