Evaluation of Wearable Digital Devices in a Phase I Clinical Trial. Issue 3 (11th January 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of Wearable Digital Devices in a Phase I Clinical Trial. Issue 3 (11th January 2019)
- Main Title:
- Evaluation of Wearable Digital Devices in a Phase I Clinical Trial
- Authors:
- Izmailova, Elena S.
McLean, Ian L.
Bhatia, Gaurav
Hather, Greg
Cantor, Matthew
Merberg, David
Perakslis, Eric D.
Benko, Christopher
Wagner, John A. - Abstract:
- Abstract : We assessed the performance of two US Food and Drug Administration (FDA) 510(k)‐cleared wearable digital devices and the operational feasibility of deploying them to augment data collection in a 10‐day residential phase I clinical trial. The Phillips Actiwatch Spectrum Pro (Actiwatch) was used to assess mobility and sleep, and the Vitalconnect HealthPatch MD (HealthPatch) was used for monitoring heart rate (HR), respiratory rate (RR), and surface skin temperature (ST). We measured data collection rates, compared device readouts with anticipated readings and conventional in‐clinic measures, investigated data limitations, and assessed user acceptability. Six of nine study participants consented; completeness of data collection was adequate (> 90% for four of six subjects). A good correlation was observed between the HealthPatch device derived and in‐clinic measures for HR (Pearson r = 0.71; P = 2.2e‐16) but this was poor for RR ( r = 0.08; P = 0.44) and ST ( r = 0.14; P = 0.14). Manual review of electrocardiogram strips recorded during reported episodes of tachycardia > 180 beats/min showed that these were artefacts. The HealthPatch was judged to be not fit‐for‐purpose because of artefacts and the need for time‐consuming manual review. The Actiwatch device was suitable for monitoring mobility, collecting derived sleep data, and facilitating the interpretation of vital sign data. These results suggest the need for fit‐for‐purpose evaluation of wearable devicesAbstract : We assessed the performance of two US Food and Drug Administration (FDA) 510(k)‐cleared wearable digital devices and the operational feasibility of deploying them to augment data collection in a 10‐day residential phase I clinical trial. The Phillips Actiwatch Spectrum Pro (Actiwatch) was used to assess mobility and sleep, and the Vitalconnect HealthPatch MD (HealthPatch) was used for monitoring heart rate (HR), respiratory rate (RR), and surface skin temperature (ST). We measured data collection rates, compared device readouts with anticipated readings and conventional in‐clinic measures, investigated data limitations, and assessed user acceptability. Six of nine study participants consented; completeness of data collection was adequate (> 90% for four of six subjects). A good correlation was observed between the HealthPatch device derived and in‐clinic measures for HR (Pearson r = 0.71; P = 2.2e‐16) but this was poor for RR ( r = 0.08; P = 0.44) and ST ( r = 0.14; P = 0.14). Manual review of electrocardiogram strips recorded during reported episodes of tachycardia > 180 beats/min showed that these were artefacts. The HealthPatch was judged to be not fit‐for‐purpose because of artefacts and the need for time‐consuming manual review. The Actiwatch device was suitable for monitoring mobility, collecting derived sleep data, and facilitating the interpretation of vital sign data. These results suggest the need for fit‐for‐purpose evaluation of wearable devices prior to their deployment in drug development studies. … (more)
- Is Part Of:
- Clinical and translational science. Volume 12:Issue 3(2019)
- Journal:
- Clinical and translational science
- Issue:
- Volume 12:Issue 3(2019)
- Issue Display:
- Volume 12, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 12
- Issue:
- 3
- Issue Sort Value:
- 2019-0012-0003-0000
- Page Start:
- 247
- Page End:
- 256
- Publication Date:
- 2019-01-11
- Subjects:
- Medicine, Experimental -- Periodicals
Medical innovations -- Periodicals
616.027 - Journal URLs:
- http://www3.interscience.wiley.com/journal/118902557/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/cts.12602 ↗
- Languages:
- English
- ISSNs:
- 1752-8054
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.255400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10206.xml