St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry. Issue 1 (December 2015)
- Main Title:
- St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry
- Authors:
- Mariscalco, Giovanni
Mariani, Silvia
Bichi, Samuele
Biondi, Andrea
Blasio, Andrea
Borsani, Paolo
Corti, Fabrizio
De Chiara, Benedetta
Gherli, Riccardo
Leva, Cristian
Russo, Claudio
Tasca, Giordano
Vanelli, Paolo
Alfieri, Ottavio
Antona, Carlo
Di Credico, Germano
Esposito, Giampiero
Gamba, Amando
Martinelli, Luigi
Menicanti, Lorenzo
Paolini, Giovanni
Beghi, Cesare - Abstract:
- Abstract Background The Trifecta aortic bioprosthesis (St. Jude Medical, Inc., St. Paul, MN, USA) is a stented pericardial heart valve with excellent preliminary results. Aim of the study was to evaluate its early clinical and hemodynamic performances in a multicenter regional registry. Methods Between January 2011 and June 2012, 178 consecutive patients undergoing aortic valve replacement with the Trifecta bioprosthesis were prospectively enrolled at 9 Italian centers. Clinical and echocardiographic data were collectedat discharge, 6-months and at 1-year postoperatively. Results The average age was 75.4 ± 7.7 years, and 95 (53 %) were men. Indication for valve replacement included stenosis in 123 patients (69 %), mixed lesions in 25 (14 %), and regurgitation in 30 (17 %). Ninety-three (52 %) patients were in NYHA functional class III/ IV. Hospital mortality accounted for 5 (2.8 %) patients. No valve-related perioperative complications were encountered. Median follow-up was 20.5 months (range: 1-34). Early (≤6 months) complications included one thromboembolic event, one major bleeding, and 3 endocarditis (2 explants). Two late (>6 months) thromboembolic events and two endocarditis (1 explant) were registered. No valve thrombosis or structural deterioration were observed after discharge. At 30-months, freedom from all-cause mortality was 87 %, freedom from valve-related mortality 99.4 %, freedom from endocarditis 97.5 %, and freedom from valve explants 98 %. At 1-year, meanAbstract Background The Trifecta aortic bioprosthesis (St. Jude Medical, Inc., St. Paul, MN, USA) is a stented pericardial heart valve with excellent preliminary results. Aim of the study was to evaluate its early clinical and hemodynamic performances in a multicenter regional registry. Methods Between January 2011 and June 2012, 178 consecutive patients undergoing aortic valve replacement with the Trifecta bioprosthesis were prospectively enrolled at 9 Italian centers. Clinical and echocardiographic data were collectedat discharge, 6-months and at 1-year postoperatively. Results The average age was 75.4 ± 7.7 years, and 95 (53 %) were men. Indication for valve replacement included stenosis in 123 patients (69 %), mixed lesions in 25 (14 %), and regurgitation in 30 (17 %). Ninety-three (52 %) patients were in NYHA functional class III/ IV. Hospital mortality accounted for 5 (2.8 %) patients. No valve-related perioperative complications were encountered. Median follow-up was 20.5 months (range: 1-34). Early (≤6 months) complications included one thromboembolic event, one major bleeding, and 3 endocarditis (2 explants). Two late (>6 months) thromboembolic events and two endocarditis (1 explant) were registered. No valve thrombosis or structural deterioration were observed after discharge. At 30-months, freedom from all-cause mortality was 87 %, freedom from valve-related mortality 99.4 %, freedom from endocarditis 97.5 %, and freedom from valve explants 98 %. At 1-year, mean gradients ranged from 8 to 16 mmHg, and effective orifice area indexes from 1.0 to 1.2 cm2 /m2 for valve sizes from 19 to27 mm, respectively. No patients had severe prosthesis-patient mismatch. Conclusions Trifecta bioprosthesis provided favourable clinical and hemodynamic results over time. … (more)
- Is Part Of:
- Journal of cardiothoracic surgery. Volume 10:Issue 1(2015)
- Journal:
- Journal of cardiothoracic surgery
- Issue:
- Volume 10:Issue 1(2015)
- Issue Display:
- Volume 10, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 1
- Issue Sort Value:
- 2015-0010-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2015-12
- Subjects:
- Aortic valve replacement -- Biomaterials -- Heart valve bioprosthesis -- Heart valve replacement
Chest -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
617.54005 - Journal URLs:
- http://pubmedcentral.com/tocrender.fcgi?journal=406&action=archive ↗
http://www.cardiothoracicsurgery.org/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13019-015-0379-6 ↗
- Languages:
- English
- ISSNs:
- 1749-8090
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10192.xml