Reliability and validity of the Four Square Step Test in patients with hip osteoarthritis before and after total hip replacement. Issue 2 (June 2019)
- Record Type:
- Journal Article
- Title:
- Reliability and validity of the Four Square Step Test in patients with hip osteoarthritis before and after total hip replacement. Issue 2 (June 2019)
- Main Title:
- Reliability and validity of the Four Square Step Test in patients with hip osteoarthritis before and after total hip replacement
- Authors:
- Batting, M.
Barker, K.L. - Abstract:
- Abstract: Objective: To determine the validity and inter- and intra-rater reliability of the Four Square Step Test (FSST) in assessing gait performance, balance and physical function for patients with hip osteoarthritis before and after total hip replacement (THR). Design: Observational, repeated measures. Setting: A specialist orthopaedic hospital. Participants: Fifty-eight participants with moderate to severe hip osteoarthritis scheduled to receive primary hip replacement within 4 months from recruitment. Main outcome measure: Time to complete the FSST, time and steps to complete the Figure of 8 Walk Test (F8W) and Berg Balance Scale score (BBS). Results: The Bland and Altman limits of agreement for intra-rater measurements of the FSST were −3.2 s to 3.5 seconds before THR and −1.5 to 2.0 seconds after THR. Limits of agreement for two different raters were −2.2 to 3.4 seconds, all with small mean differences indicating little bias between raters or replications. Concurrent validity was assessed, and the FSST correlated highly with the F8W ( r = 0.7, P < 0.001) and moderately with the BBS ( r = 0.6, P < 0.001). Only one participant was rated as being at moderate risk of falls on the BBS, with the other participants scoring low; only one participant failed to complete the F8W. This is in contrast to the FSST, which 21 people failed to complete pre-operatively. Conclusions: The FSST is a valid and reliable measure of multi-directional stepping speed and balance, giving aAbstract: Objective: To determine the validity and inter- and intra-rater reliability of the Four Square Step Test (FSST) in assessing gait performance, balance and physical function for patients with hip osteoarthritis before and after total hip replacement (THR). Design: Observational, repeated measures. Setting: A specialist orthopaedic hospital. Participants: Fifty-eight participants with moderate to severe hip osteoarthritis scheduled to receive primary hip replacement within 4 months from recruitment. Main outcome measure: Time to complete the FSST, time and steps to complete the Figure of 8 Walk Test (F8W) and Berg Balance Scale score (BBS). Results: The Bland and Altman limits of agreement for intra-rater measurements of the FSST were −3.2 s to 3.5 seconds before THR and −1.5 to 2.0 seconds after THR. Limits of agreement for two different raters were −2.2 to 3.4 seconds, all with small mean differences indicating little bias between raters or replications. Concurrent validity was assessed, and the FSST correlated highly with the F8W ( r = 0.7, P < 0.001) and moderately with the BBS ( r = 0.6, P < 0.001). Only one participant was rated as being at moderate risk of falls on the BBS, with the other participants scoring low; only one participant failed to complete the F8W. This is in contrast to the FSST, which 21 people failed to complete pre-operatively. Conclusions: The FSST is a valid and reliable measure of multi-directional stepping speed and balance, giving a more informative measure of gait performance than the F8W and BBS, and is feasible for use in a clinical population of patients both before and after THR. … (more)
- Is Part Of:
- Physiotherapy. Volume 105:Issue 2(2019)
- Journal:
- Physiotherapy
- Issue:
- Volume 105:Issue 2(2019)
- Issue Display:
- Volume 105, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 105
- Issue:
- 2
- Issue Sort Value:
- 2019-0105-0002-0000
- Page Start:
- 244
- Page End:
- 253
- Publication Date:
- 2019-06
- Subjects:
- Outcome assessments -- Gait -- Balance -- Osteoarthritis -- Total hip replacement -- Reproducibility of results
Physical therapy -- Periodicals
Therapeutics, Physiological -- Periodicals
615.8205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00319406 ↗
http://www.elsevier.com/journals ↗
http://www.csp.org.uk/libraryandinformation/publications/physiotherapyjournal.cfm ↗ - DOI:
- 10.1016/j.physio.2018.07.014 ↗
- Languages:
- English
- ISSNs:
- 0031-9406
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6489.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10152.xml