Effects of housing system, floor type and temperature on ammonia and methane emissions from dairy farming: A meta-analysis. (June 2019)
- Record Type:
- Journal Article
- Title:
- Effects of housing system, floor type and temperature on ammonia and methane emissions from dairy farming: A meta-analysis. (June 2019)
- Main Title:
- Effects of housing system, floor type and temperature on ammonia and methane emissions from dairy farming: A meta-analysis
- Authors:
- Poteko, Jernej
Zähner, Michael
Schrade, Sabine - Abstract:
- Abstract : This study provides an overview of ammonia (NH3 ) and methane (CH4 ) emissions from measurements conducted on a practical scale in different dairy housing systems. In addition, the influence of housing system, floor type and air temperature on NH3 and CH4 emissions is statistically analysed using the wide range of data provided by various studies. A number of overviews of NH3 and CH4 emission data differentiated according to dairy housing system and season exhibit wide ranges of emission data both between and within individual studies. Although differences in both farm conditions (e.g. herd size, breed, animal productivity, area ratios, ventilation, feeding strategy, management) and measurement concept (e.g. analytics, methods, measurement duration, single farm vs. several farms) make data comparison difficult, clear effects on NH3 and CH4 emissions can be demonstrated. The NH3 emissions of tied housing are lower than those of loose housing systems with cubicles (p = 0.001). Furthermore, within the 'loose housing system with cubicles' category, air temperature influences both NH3 (p < 0.001) and CH4 (p < 0.001) emissions. As the air temperature rises, so do the emissions. This also leads to a close positive correlation between NH3 and CH4 emissions (r = 0.80). There are no differences for either NH3 or CH4 emissions (p = 0.76 and p = 0.49, respectively) between the 'perforated' and 'solid' floor types in loose housing systems with cubicles. Highlights: The rangeAbstract : This study provides an overview of ammonia (NH3 ) and methane (CH4 ) emissions from measurements conducted on a practical scale in different dairy housing systems. In addition, the influence of housing system, floor type and air temperature on NH3 and CH4 emissions is statistically analysed using the wide range of data provided by various studies. A number of overviews of NH3 and CH4 emission data differentiated according to dairy housing system and season exhibit wide ranges of emission data both between and within individual studies. Although differences in both farm conditions (e.g. herd size, breed, animal productivity, area ratios, ventilation, feeding strategy, management) and measurement concept (e.g. analytics, methods, measurement duration, single farm vs. several farms) make data comparison difficult, clear effects on NH3 and CH4 emissions can be demonstrated. The NH3 emissions of tied housing are lower than those of loose housing systems with cubicles (p = 0.001). Furthermore, within the 'loose housing system with cubicles' category, air temperature influences both NH3 (p < 0.001) and CH4 (p < 0.001) emissions. As the air temperature rises, so do the emissions. This also leads to a close positive correlation between NH3 and CH4 emissions (r = 0.80). There are no differences for either NH3 or CH4 emissions (p = 0.76 and p = 0.49, respectively) between the 'perforated' and 'solid' floor types in loose housing systems with cubicles. Highlights: The range of NH3 and CH4 emissions data for dairy housing systems is wide. NH3 emissions from tied housing are lower than from loose housing with cubicles. NH3 and CH4 emissions from perforated and solid floors do not differ significantly. NH3 and CH4 emissions from loose housing with cubicles increase with temperature. … (more)
- Is Part Of:
- Biosystems engineering. Volume 182(2019)
- Journal:
- Biosystems engineering
- Issue:
- Volume 182(2019)
- Issue Display:
- Volume 182, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 182
- Issue:
- 2019
- Issue Sort Value:
- 2019-0182-2019-0000
- Page Start:
- 16
- Page End:
- 28
- Publication Date:
- 2019-06
- Subjects:
- Tied housing -- Loose housing -- Solid floor -- Perforated floor -- Influencing factors
Bioengineering -- Periodicals
Agricultural engineering -- Periodicals
Biological systems -- Periodicals
Génie rural -- Périodiques
Systèmes biologiques -- Périodiques
631 - Journal URLs:
- http://www.sciencedirect.com/science/journal/15375110 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biosystemseng.2019.03.012 ↗
- Languages:
- English
- ISSNs:
- 1537-5110
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2089.670500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10153.xml