Two-phase gas-liquid flow in concentric and fully eccentric annuli. Part I: Flow patterns, holdup, slip ratio and pressure gradient. (10th August 2019)
- Record Type:
- Journal Article
- Title:
- Two-phase gas-liquid flow in concentric and fully eccentric annuli. Part I: Flow patterns, holdup, slip ratio and pressure gradient. (10th August 2019)
- Main Title:
- Two-phase gas-liquid flow in concentric and fully eccentric annuli. Part I: Flow patterns, holdup, slip ratio and pressure gradient
- Authors:
- Ibarra, Roberto
Nossen, Jan
Tutkun, Murat - Abstract:
- Highlights: Gas-liquid flows in concentric and fully eccentric annuli were studied. Flows in fully eccentric annulus show a more well-defined structure than concentric. Concentric annulus causes larger pressure drop than in fully eccentric. Pipe wettability seems to affect the flow behaviour especially in concentric annulus. Abstract: Horizontal and upward low-inclination gas-water and gas-oil flows are investigated using an annulus pipe configuration in a high-pressure system (∼400 kPa). The annulus test section, or the so-called pipe-in-pipe configuration, consists of an outer pipe of 99 mm inside diameter and an inner pipe of 50 mm outside diameter. Two different vertical positions of the inner pipe with respect to outer pipe have been tested; namely concentric configuration where both pipes have the same centreline and fully eccentric where the inner pipe is placed at the bottom wall of outer pipe. The flow is studied using high-speed photography, differential pressure transducers, and broad-beam gamma densitometers to characterise the flow as function of the liquid phase properties, annulus eccentricity, and pipe inclination. Flow regime maps reveal that slug flow appears to be the most common flow feature across the conditions studied in this paper. Flow in the eccentric annulus shows a more consistent behaviour ( i.e. well-defined flow structures axially and in time) than that observed in the concentric annulus. Gas-oil flows show more stable phase fraction behaviourHighlights: Gas-liquid flows in concentric and fully eccentric annuli were studied. Flows in fully eccentric annulus show a more well-defined structure than concentric. Concentric annulus causes larger pressure drop than in fully eccentric. Pipe wettability seems to affect the flow behaviour especially in concentric annulus. Abstract: Horizontal and upward low-inclination gas-water and gas-oil flows are investigated using an annulus pipe configuration in a high-pressure system (∼400 kPa). The annulus test section, or the so-called pipe-in-pipe configuration, consists of an outer pipe of 99 mm inside diameter and an inner pipe of 50 mm outside diameter. Two different vertical positions of the inner pipe with respect to outer pipe have been tested; namely concentric configuration where both pipes have the same centreline and fully eccentric where the inner pipe is placed at the bottom wall of outer pipe. The flow is studied using high-speed photography, differential pressure transducers, and broad-beam gamma densitometers to characterise the flow as function of the liquid phase properties, annulus eccentricity, and pipe inclination. Flow regime maps reveal that slug flow appears to be the most common flow feature across the conditions studied in this paper. Flow in the eccentric annulus shows a more consistent behaviour ( i.e. well-defined flow structures axially and in time) than that observed in the concentric annulus. Gas-oil flows show more stable phase fraction behaviour across the cross-section compared to that observed in gas-water flows in which the interface shows significant activity promoting the formation of droplets and ligaments that break from the liquid film. This is especially the case with the concentric annulus configuration. The oil phase regardless of the geometrical configuration tends to fully wet the pipe (made of PVC) as the gas velocity increases, creating a continuous film along the pipe walls. Conversely, the thin film in gas-water flow is not continuous. Discontinuity in the thin film increases with an increase in effective pipe roughness. Given the same inlet flow conditions, the concentric annulus configuration causes larger pressure drop along the pipe than that obtained in the eccentric. … (more)
- Is Part Of:
- Chemical engineering science. Volume 203(2019)
- Journal:
- Chemical engineering science
- Issue:
- Volume 203(2019)
- Issue Display:
- Volume 203, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 203
- Issue:
- 2019
- Issue Sort Value:
- 2019-0203-2019-0000
- Page Start:
- 489
- Page End:
- 500
- Publication Date:
- 2019-08-10
- Subjects:
- Annulus flow -- Concentric -- Fully eccentric -- Flow regimes -- Flow regime transitions -- Liquid holdup
Chemical engineering -- Periodicals
Génie chimique -- Périodiques
Chemical engineering
Periodicals
Electronic journals
660 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00092509 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ces.2019.01.064 ↗
- Languages:
- English
- ISSNs:
- 0009-2509
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3146.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10145.xml