Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis. Issue 1 (December 2015)
- Main Title:
- Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis
- Authors:
- Prifti, Edvin
Bonacchi, Massimo
Ademaj, Fadil
Giunti, Gabriele
Esposito, Giampiero
Baboci, Arben
Bajraktari, Gani
Veshti, Altin
Demiraj, Aurel
Vanini, Vittorio - Abstract:
- Abstract Background The aim of the present study is to compare the early and mid-term clinical and hemodynamic results of the aortic valve replacement (AVR) with a St Jude Medical Regent 19-mm prosthesis (SJMR-19) versus Carpentied-Edwars bovine pericardial 19-mm valve (CE-19). Methods Between January 2002 and January 2012, 265 patients (Group I) and 58 patients (Group II) with underwent AVR with a SJMR-19 and CE-19 respectively. There were no significant differences between groups regarding the demographic and preoperative echocardiographic data. Thirty-six patients in Group I and 4 in Group II required annulus enlargement in association or not with septal myectomy. The mean follow-up was 34 ± 18.5 months (range 5–60 months). Results There were 14 (5.3 %) hospital deaths in Group I versus 4 (6.8 %) in Group II (p = 0.86). The multivariate logistic regression analysis identified the LVEF ≤ 35 % (p = 0.001), combined operation (p = 0.0005), CPB (p = 0.033), age (p = 0.011), annulus enlargement (p = 0.0009), reoperation (p = 0.039) and chronic renal failure (p = 0.011) as strong predictors for early postoperative death. Within 1 year after surgery peak pulmonary artery pressure, interventricular septal and left ventricular posterior wall thickness decreased significantly in both groups. The M-TPG was 15.7 ± 6.5 mmHg in Group I versus 17 ± 7 mmHg in Group II (p = 0.19). The multivariate regression analysis revealed the annulus enlargement (p = 0.018), small EOAi (pAbstract Background The aim of the present study is to compare the early and mid-term clinical and hemodynamic results of the aortic valve replacement (AVR) with a St Jude Medical Regent 19-mm prosthesis (SJMR-19) versus Carpentied-Edwars bovine pericardial 19-mm valve (CE-19). Methods Between January 2002 and January 2012, 265 patients (Group I) and 58 patients (Group II) with underwent AVR with a SJMR-19 and CE-19 respectively. There were no significant differences between groups regarding the demographic and preoperative echocardiographic data. Thirty-six patients in Group I and 4 in Group II required annulus enlargement in association or not with septal myectomy. The mean follow-up was 34 ± 18.5 months (range 5–60 months). Results There were 14 (5.3 %) hospital deaths in Group I versus 4 (6.8 %) in Group II (p = 0.86). The multivariate logistic regression analysis identified the LVEF ≤ 35 % (p = 0.001), combined operation (p = 0.0005), CPB (p = 0.033), age (p = 0.011), annulus enlargement (p = 0.0009), reoperation (p = 0.039) and chronic renal failure (p = 0.011) as strong predictors for early postoperative death. Within 1 year after surgery peak pulmonary artery pressure, interventricular septal and left ventricular posterior wall thickness decreased significantly in both groups. The M-TPG was 15.7 ± 6.5 mmHg in Group I versus 17 ± 7 mmHg in Group II (p = 0.19). The multivariate regression analysis revealed the annulus enlargement (p = 0.018), small EOAi (p = 0.00004), postoperative LVMi (p = 0.0001) and BSA (p = 0.019) as strong predictors for higher M-TPG. The postoperative LVMi was 119 ± 22.5 gm/m2 in Group I and 122 ± 22 gm/m2 in Group II (p = 0.37), significantly lower than the respective preoperative values 162.5 ± 34 gm/m2 (Group I) and 168 ± 30 gm/m2 (Group II). The actuarial survival and cumulative free-reoperation actuarial survival at 5 years follow-up were 96.7 and 94.5 % respectively in Group I and 97 and 91 % in Group II.. There were non significant differences between groups regarding the actuarial survival and cumulative free-reoperation survival. The Cox model identified the older age (p = 0.022), LVEF ≤ 35 % (p = 0.009), reoperation (p = 0.018), combined surgery (p = 0.00075) and annulus enlargement (p = 0.033) as strong predictors for poor actuarial free-reoperation survival. Conclusions Both the SJMR-19 and CE-19 offers excellent postoperative clinical and hemodynamic outcome in patients with small aortic annulus. The LV hypertrophy and transvalvular gradients are reduced significantly indenpendently of the employed SJMR-19 or CE-19 prosthesis. Our data support recent suggestions that small valve size does not influence intermediate free-reoperation survival. The CE-19 is an excellent alternative to SJMR-19 in old patients. … (more)
- Is Part Of:
- Journal of cardiothoracic surgery. Volume 10:Issue 1(2015)
- Journal:
- Journal of cardiothoracic surgery
- Issue:
- Volume 10:Issue 1(2015)
- Issue Display:
- Volume 10, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 1
- Issue Sort Value:
- 2015-0010-0001-0000
- Page Start:
- 1
- Page End:
- 15
- Publication Date:
- 2015-12
- Subjects:
- St Jude Medical Regent 19-mm mechanical aortic prothesis -- Carpentier-Edwards bioprothesis -- Indexed effective orficice area -- Indexed left ventricular mass
Chest -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
617.54005 - Journal URLs:
- http://pubmedcentral.com/tocrender.fcgi?journal=406&action=archive ↗
http://www.cardiothoracicsurgery.org/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13019-015-0361-3 ↗
- Languages:
- English
- ISSNs:
- 1749-8090
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10123.xml