Load evaluation of the da Vinci surgical system for transoral robotic surgery. Issue 4 (December 2015)
- Record Type:
- Journal Article
- Title:
- Load evaluation of the da Vinci surgical system for transoral robotic surgery. Issue 4 (December 2015)
- Main Title:
- Load evaluation of the da Vinci surgical system for transoral robotic surgery
- Authors:
- Fujiwara, Kazunori
Fukuhara, Takahiro
Niimi, Koji
Sato, Takahiro
Kitano, Hiroya - Abstract:
- Abstract Transoral robotic surgery, performed with the da Vinci surgical system (da Vinci), is a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a 3-dimensional magnified view and ability to see and work around curves or angles. However, the current da Vinci surgical system does not provide haptic feedback. This is problematic because the potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury and mandibular fracture. To assess the potential for intraoperative injuries, we measured the load of the endoscope and the instrument of the da Vinci Si surgical system. We pressed the endoscope and instrument of the da Vinci Si against Load cell six times each and measured the dynamic load and the time-to-maximum load. We also struck the da Vinci Si endoscope and instrument against the Load cell six times each and measured the impact load. The maximum dynamic load was 7.27 ± 1.31 kg for the endoscope and 1.90 ± 0.72 for the instrument. The corresponding time-to-maximum loads were 1.72 ± 0.22 and 1.29 ± 0.34 s, but the impact loads were significantly lower than the dynamic load. It remains possible that a major load is exerted on adjacent structures by continuous contact with the endoscope and instrument of da Vinci Si. However, there is a minor delay in reaching the maximum load. Careful monitoring by an on-site assistant may,Abstract Transoral robotic surgery, performed with the da Vinci surgical system (da Vinci), is a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a 3-dimensional magnified view and ability to see and work around curves or angles. However, the current da Vinci surgical system does not provide haptic feedback. This is problematic because the potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury and mandibular fracture. To assess the potential for intraoperative injuries, we measured the load of the endoscope and the instrument of the da Vinci Si surgical system. We pressed the endoscope and instrument of the da Vinci Si against Load cell six times each and measured the dynamic load and the time-to-maximum load. We also struck the da Vinci Si endoscope and instrument against the Load cell six times each and measured the impact load. The maximum dynamic load was 7.27 ± 1.31 kg for the endoscope and 1.90 ± 0.72 for the instrument. The corresponding time-to-maximum loads were 1.72 ± 0.22 and 1.29 ± 0.34 s, but the impact loads were significantly lower than the dynamic load. It remains possible that a major load is exerted on adjacent structures by continuous contact with the endoscope and instrument of da Vinci Si. However, there is a minor delay in reaching the maximum load. Careful monitoring by an on-site assistant may, therefore, help prevent contiguous injury. … (more)
- Is Part Of:
- Journal of robotic surgery. Volume 9:Issue 4(2015)
- Journal:
- Journal of robotic surgery
- Issue:
- Volume 9:Issue 4(2015)
- Issue Display:
- Volume 9, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 9
- Issue:
- 4
- Issue Sort Value:
- 2015-0009-0004-0000
- Page Start:
- 315
- Page End:
- 319
- Publication Date:
- 2015-12
- Subjects:
- Load -- da Vinci -- Transoral robotic surgery -- Intraoperative injury
Robotics -- Periodicals
Robotics in medicine -- Periodicals
Robotics -- Periodicals
Surgical Procedures, Minimally Invasive -- Periodicals
Electronic journals
617.9 - Journal URLs:
- http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/270795 ↗
http://www.springerlink.com/content/120470/ ↗
http://www.springerlink.com/openurl.asp?genre=journal&issn=1863-2483 ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1007/s11701-015-0533-0 ↗
- Languages:
- English
- ISSNs:
- 1863-2483
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5052.109000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10124.xml