A comparison of two designs for earcons conveying pulse oximetry information. (July 2019)
- Record Type:
- Journal Article
- Title:
- A comparison of two designs for earcons conveying pulse oximetry information. (July 2019)
- Main Title:
- A comparison of two designs for earcons conveying pulse oximetry information
- Authors:
- Lim, Hai-Ping
Sanderson, Penelope - Abstract:
- Abstract: We performed a randomised controlled trial comparing two kinds of earcons that could provide intermittent pulse oximetry information about a patient's oxygen saturation (SpO2 ) and heart rate (HR). Timbre-earcons represented SpO2 levels with different levels of timbre, and pitch-earcons with different levels of pitch. Both kinds of earcons represented HR with tremolo. Participants using pitch-earcons identified SpO2 levels alone, and both SpO2 plus HR levels, significantly better than participants using timbre-earcons: p < .001 in both cases. However, there was no difference between earcon conditions in how effectively HR was identified, p = .422. For both kinds of earcons, identification of SpO2 levels was more compromised by simultaneous changes in HR than identification of HR levels was compromised by simultaneous changes in SpO2, suggesting asymmetric integrality. Overall, pitch-earcons may provide a better intermittent auditory pulse oximetry display than timbre-earcons, especially for clinical contexts when quiet is needed. Highlights: Pulse oximetry earcons provide periodic clinical updates with little extra noise. Earcons can map oxygen saturation to timbre or pitch, and heart rate to tremolo. Pitch-earcons supported better identification of saturation than timbre-earcons. Interference between dimensions for both earcons suggests asymmetrical integrality. Pitch-earcons may support periodic pulse oximetry updates better than timbre-earcons.
- Is Part Of:
- Applied ergonomics. Volume 78(2019)
- Journal:
- Applied ergonomics
- Issue:
- Volume 78(2019)
- Issue Display:
- Volume 78, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 78
- Issue:
- 2019
- Issue Sort Value:
- 2019-0078-2019-0000
- Page Start:
- 110
- Page End:
- 119
- Publication Date:
- 2019-07
- Subjects:
- Auditory displays -- Pulse oximetry -- Earcons
Human engineering -- Periodicals
620.82 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00036870 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apergo.2019.01.013 ↗
- Languages:
- English
- ISSNs:
- 0003-6870
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1572.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10123.xml