Wild, Jim M. - Abstract:
- Abstract : Purpose: To develop and assess a method for acquiring coregistered proton anatomical and hyperpolarized 129 Xe ventilation MR images of the lungs with compressed sensing (CS) in a single breath hold. Methods: Retrospective CS simulations were performed on fully sampled ventilation images acquired from one healthy smoker to optimize reconstruction parameters. Prospective same‐breath anatomical and ventilation images were also acquired in five ex‐smokers with an acceleration factor of 3 for hyperpolarized 129 Xe images, and were compared to fully sampled images acquired during the same session. The following metrics were used to assess data fidelity: mean absolute error (MAE), root mean square error, and linear regression of the signal intensity between fully sampled and undersampled images. The effect of CS reconstruction on two quantitative imaging metrics routinely reported [percentage ventilated volume (%VV) and heterogeneity score] was also investigated. Results: Retrospective simulations showed good agreement between fully sampled and CS‐reconstructed (acceleration factor of 3) images with MAE (root mean square error) of 3.9% (4.5%). The prospective same‐breath images showed a good match in ventilation distribution with an average R 2 of 0.76 from signal intensity linear regression and a negligible systematic bias of +0.1% in %VV calculation. A bias of −1.8% in the heterogeneity score was obtained. Conclusion: With CS, high‐quality 3D images of hyperpolarizedAbstract : Purpose: To develop and assess a method for acquiring coregistered proton anatomical and hyperpolarized 129 Xe ventilation MR images of the lungs with compressed sensing (CS) in a single breath hold. Methods: Retrospective CS simulations were performed on fully sampled ventilation images acquired from one healthy smoker to optimize reconstruction parameters. Prospective same‐breath anatomical and ventilation images were also acquired in five ex‐smokers with an acceleration factor of 3 for hyperpolarized 129 Xe images, and were compared to fully sampled images acquired during the same session. The following metrics were used to assess data fidelity: mean absolute error (MAE), root mean square error, and linear regression of the signal intensity between fully sampled and undersampled images. The effect of CS reconstruction on two quantitative imaging metrics routinely reported [percentage ventilated volume (%VV) and heterogeneity score] was also investigated. Results: Retrospective simulations showed good agreement between fully sampled and CS‐reconstructed (acceleration factor of 3) images with MAE (root mean square error) of 3.9% (4.5%). The prospective same‐breath images showed a good match in ventilation distribution with an average R 2 of 0.76 from signal intensity linear regression and a negligible systematic bias of +0.1% in %VV calculation. A bias of −1.8% in the heterogeneity score was obtained. Conclusion: With CS, high‐quality 3D images of hyperpolarized 129 Xe ventilation (resolution 4.2 × 4.2 × 7.5 mm 3 ) can be acquired with coregistered 1 H anatomical MRI in a 15‐s breath hold. The accelerated acquisition time dispenses with the need for registration between separate breath‐hold 129 Xe and 1 H MRI, enabling more accurate %VV calculation. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 82:Issue 1(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 82:Issue 1(2019)
- Issue Display:
- Volume 82, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 1
- Issue Sort Value:
- 2019-0082-0001-0000
- Page Start:
- 342
- Page End:
- 347
- Publication Date:
- 2019-02-28
- Subjects:
- compressed sensing -- hyperpolarized129Xe gas -- lung MRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27713 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10110.xml