Edge detector‐based automatic segmentation of the skin layers and application to moisturization in high‐resolution 3 Tesla magnetic resonance imaging. Issue 3 (18th January 2019)
- Record Type:
- Journal Article
- Title:
- Edge detector‐based automatic segmentation of the skin layers and application to moisturization in high‐resolution 3 Tesla magnetic resonance imaging. Issue 3 (18th January 2019)
- Main Title:
- Edge detector‐based automatic segmentation of the skin layers and application to moisturization in high‐resolution 3 Tesla magnetic resonance imaging
- Authors:
- Ognard, Julien
Mesrar, Jawad
Benhoumich, Younes
Misery, Laurent
Burdin, Valerie
Ben Salem, Douraied - Abstract:
- Abstract: Introduction: Previous studies have demonstrated the feasibility to explore moisturization with quantification imaging based on T2 mapping. The aim of this study was to describe and validate the first robust automated method to segment the first layers of the skin. Materials and Methods: Data were picked from a previous study that included 35 healthy subjects who underwent a 3T MRI (multi spin echo calculation T2‐weighted sequence) with a microscopic coil on the left heel before and one hour after moisturization. The automatic algorithm was composed of the T2 map generation, a Canny filter, a selection of boundaries, and a local regression to delimitate stratum corneum, epidermis, and dermis. An automated affine registration was applied between the exams before and after moisturization. Results: The failure rate of the algorithm was below 5%. Mean computation time was 139.12s. There was a significant and strong correlation between the automatic measurements and the manual ones for the T2 values ( ρ : 0.905, P < 0.001) and for the thickness measurements ( ρ : 0.8663; P < 0.001). For registration, mean of the Dice index was 0.64 [0.47; 0.80] and of the Hausdorff distance was 0.29 mm 95% CI: [0.28; 0.30]. Conclusion: The proposed automatic method to study the first skin layers in 3T MRI using micro‐coils was robust and described T2 values and thickness measurements with a strong correlation to manual measurements. The use of an automated affine registration couldAbstract: Introduction: Previous studies have demonstrated the feasibility to explore moisturization with quantification imaging based on T2 mapping. The aim of this study was to describe and validate the first robust automated method to segment the first layers of the skin. Materials and Methods: Data were picked from a previous study that included 35 healthy subjects who underwent a 3T MRI (multi spin echo calculation T2‐weighted sequence) with a microscopic coil on the left heel before and one hour after moisturization. The automatic algorithm was composed of the T2 map generation, a Canny filter, a selection of boundaries, and a local regression to delimitate stratum corneum, epidermis, and dermis. An automated affine registration was applied between the exams before and after moisturization. Results: The failure rate of the algorithm was below 5%. Mean computation time was 139.12s. There was a significant and strong correlation between the automatic measurements and the manual ones for the T2 values ( ρ : 0.905, P < 0.001) and for the thickness measurements ( ρ : 0.8663; P < 0.001). For registration, mean of the Dice index was 0.64 [0.47; 0.80] and of the Hausdorff distance was 0.29 mm 95% CI: [0.28; 0.30]. Conclusion: The proposed automatic method to study the first skin layers in 3T MRI using micro‐coils was robust and described T2 values and thickness measurements with a strong correlation to manual measurements. The use of an automated affine registration could also permit the generation of a mapping for a visual assessment of moisturization. … (more)
- Is Part Of:
- Skin research and technology. Volume 25:Issue 3(2019)
- Journal:
- Skin research and technology
- Issue:
- Volume 25:Issue 3(2019)
- Issue Display:
- Volume 25, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 25
- Issue:
- 3
- Issue Sort Value:
- 2019-0025-0003-0000
- Page Start:
- 339
- Page End:
- 346
- Publication Date:
- 2019-01-18
- Subjects:
- 3T MRI -- canny filter -- moisturization -- registration -- segmentation -- skin -- T2 mapping
Skin -- Research -- Periodicals
Skin -- Diseases -- Periodicals
Skin -- Physiology -- Periodicals
616.5 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0909-752X&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0846 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/srt.12654 ↗
- Languages:
- English
- ISSNs:
- 0909-752X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8295.948000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10115.xml