Reproducibility of the durometer and myoton devices for skin stiffness measurement in healthy subjects. Issue 3 (10th November 2018)
- Record Type:
- Journal Article
- Title:
- Reproducibility of the durometer and myoton devices for skin stiffness measurement in healthy subjects. Issue 3 (10th November 2018)
- Main Title:
- Reproducibility of the durometer and myoton devices for skin stiffness measurement in healthy subjects
- Authors:
- Dellalana, Laura E.
Chen, Fuyao
Vain, Arved
Gandelman, Jocelyn S.
Põldemaa, Mihkel
Chen, Heidi
Tkaczyk, Eric R. - Abstract:
- Abstract: Background: Clinical assessment of skin stiffness is unreliable in many applications. The durometer, an industrial device to measure hardness, has previously been applied in scleroderma. The Myoton is a noninvasive handheld device for assessing soft tissue biomechanical parameters. Materials and Methods: We evaluated the reproducibility of both devices in six healthy subjects in the volar forearm, dorsal forearm, upper arm, shin, and calf bilaterally. The intraclass correlation coefficient (ICC) was used as a measure of reproducibility among three observers. Results: The interobserver intraclass correlation coefficient (ICC) of overall stiffness for the Myoton was 0.74 [95% confidence interval (CI) 0.45‐1.00] and 0.71 [0.39‐1.00] for the durometer. Coefficient of variation (CV) for the Myoton was 6.4% [range 1.3‐12.1] and 7.6% [range 4.4‐13.8] for the durometer. Myoton and durometer values had a Pearson correlation of 0.69. The intraobserver Myoton ICC was 0.89 [0.74‐1.00] and CV 3.1% [range 1.6‐5.0]. The 95% confidence minimal detectable change by the Myoton for a single observer is 32.4 N/m, which is 7.6% of the average subject's overall stiffness. Conclusion: The Myoton demonstrated high reproducibility, particularly in the overall stiffness parameter, and merits further investigation to assess disease progression and treatment efficacy.
- Is Part Of:
- Skin research and technology. Volume 25:Issue 3(2019)
- Journal:
- Skin research and technology
- Issue:
- Volume 25:Issue 3(2019)
- Issue Display:
- Volume 25, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 25
- Issue:
- 3
- Issue Sort Value:
- 2019-0025-0003-0000
- Page Start:
- 289
- Page End:
- 293
- Publication Date:
- 2018-11-10
- Subjects:
- durometer -- intraclass correlation coefficient -- myoton -- sclerosis -- stiffness
Skin -- Research -- Periodicals
Skin -- Diseases -- Periodicals
Skin -- Physiology -- Periodicals
616.5 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0909-752X&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0846 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/srt.12646 ↗
- Languages:
- English
- ISSNs:
- 0909-752X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8295.948000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10107.xml