Effects of extracorporeal membrane oxygenation pump flow, backflow cannulae, mean arterial blood pressure, and pulse pressure on Doppler-derived flow velocities of the lower limbs in patients on peripheral veno-arterial extracorporeal membrane oxygenation: A pilot study. Issue 3 (May 2019)
- Record Type:
- Journal Article
- Title:
- Effects of extracorporeal membrane oxygenation pump flow, backflow cannulae, mean arterial blood pressure, and pulse pressure on Doppler-derived flow velocities of the lower limbs in patients on peripheral veno-arterial extracorporeal membrane oxygenation: A pilot study. Issue 3 (May 2019)
- Main Title:
- Effects of extracorporeal membrane oxygenation pump flow, backflow cannulae, mean arterial blood pressure, and pulse pressure on Doppler-derived flow velocities of the lower limbs in patients on peripheral veno-arterial extracorporeal membrane oxygenation: A pilot study
- Authors:
- Breeding, Jeff
Hamp, Thomas
Grealy, Robert
Nair, Priya
Iyer, Arjun
Kawanishi, Yujiro - Abstract:
- Abstract: Background: Reported rates of limb ischaemia on peripheral veno-arterial extracorporeal membrane oxygenation (pVA ECMO) vary from 1–52%. Objectives: Primary: To explore (i) the feasibility for appropriately trained intensive care unit staff to measure Doppler derived flow velocities of the lower limbs for patients on pVA ECMO; and (ii) whether these measurements are clinically useful. Secondary: explore the relationship between ECMO pump flow, backflow cannulae (BFC) properties, mean arterial blood pressure (MAP), and pulse pressure on flow velocities. Method: Inclusion criteria: age>18 years, on pVA ECMO >24 hours. Exclusion criteria: any guardianship limitations and patients without a BFC. Serial patients receiving pVA-ECMO over a 10 month period had Doppler derived flow velocities of the lower limbs sampled. Simultaneously, other pertinent parameters were recorded. 80% inclusion was considered clinically feasible. Study personnel were asked for feedback regarding the ease and usefulness of studies. Results: 15 of 17 patients were included: 88% inclusion. Mean peak systolic velocity (PSV) in the cannulated limb was 31 ± 29 cm/s in the dorsalis pedis (DP) and 27 ± 18 cm/s posterior tibial (PT). Similar flows were recorded in the non-cannulated limbs (DP 34 ± 29 cm/s, PT 44 ± 36 cm/s; P > 0.05). PSV was positively correlated with pulse pressure in cannulated and non-cannulated limbs respectively (r = 0.63, P < 0.05; r = 0.67 and P < 0.05). There was no significantAbstract: Background: Reported rates of limb ischaemia on peripheral veno-arterial extracorporeal membrane oxygenation (pVA ECMO) vary from 1–52%. Objectives: Primary: To explore (i) the feasibility for appropriately trained intensive care unit staff to measure Doppler derived flow velocities of the lower limbs for patients on pVA ECMO; and (ii) whether these measurements are clinically useful. Secondary: explore the relationship between ECMO pump flow, backflow cannulae (BFC) properties, mean arterial blood pressure (MAP), and pulse pressure on flow velocities. Method: Inclusion criteria: age>18 years, on pVA ECMO >24 hours. Exclusion criteria: any guardianship limitations and patients without a BFC. Serial patients receiving pVA-ECMO over a 10 month period had Doppler derived flow velocities of the lower limbs sampled. Simultaneously, other pertinent parameters were recorded. 80% inclusion was considered clinically feasible. Study personnel were asked for feedback regarding the ease and usefulness of studies. Results: 15 of 17 patients were included: 88% inclusion. Mean peak systolic velocity (PSV) in the cannulated limb was 31 ± 29 cm/s in the dorsalis pedis (DP) and 27 ± 18 cm/s posterior tibial (PT). Similar flows were recorded in the non-cannulated limbs (DP 34 ± 29 cm/s, PT 44 ± 36 cm/s; P > 0.05). PSV was positively correlated with pulse pressure in cannulated and non-cannulated limbs respectively (r = 0.63, P < 0.05; r = 0.67 and P < 0.05). There was no significant correlation between PSV and MAP. ECMO pump flow and BFC were negatively correlated with PSV (r = −0.51, P < 0.05; r = −0.43, P < 0.05). Conclusion: It is generally feasible for ICU staff to measure flow velocities of the lower limbs for patients on pVA ECMO. It remains unclear how clinically useful these measurements are. Doppler derived flow velocities of arteries of the lower limbs of patients on pVA ECMO appear different to non-ECMO patients. PSV in the lower limbs of patients on pVA ECMO seems to be more related to pulse pressure than to other haemodynamic parameters. … (more)
- Is Part Of:
- Australian critical care. Volume 32:Issue 3(2019)
- Journal:
- Australian critical care
- Issue:
- Volume 32:Issue 3(2019)
- Issue Display:
- Volume 32, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2019-0032-0003-0000
- Page Start:
- 206
- Page End:
- 212
- Publication Date:
- 2019-05
- Subjects:
- Extracorporeal membrane oxygenation -- ECMO -- Limb ischaemia -- Doppler derived flow velocities
Intensive care nursing -- Periodicals
Intensive care nursing -- Australia -- Periodicals
Electronic journals
616.028 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10367314 ↗
http://www.informit.com.au/show.asp?id=MEDITEXT ↗
http://search.informit.com.au/search;res=MEDITEXT;search=IS=1036-7314 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.aucc.2018.04.002 ↗
- Languages:
- English
- ISSNs:
- 1036-7314
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1798.264300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10104.xml