Influence of the time of day on axial length and choroidal thickness changes to hyperopic and myopic defocus in human eyes. (May 2019)
- Record Type:
- Journal Article
- Title:
- Influence of the time of day on axial length and choroidal thickness changes to hyperopic and myopic defocus in human eyes. (May 2019)
- Main Title:
- Influence of the time of day on axial length and choroidal thickness changes to hyperopic and myopic defocus in human eyes
- Authors:
- Moderiano, Daniel
Do, Michelle
Hobbs, Sam
Lam, Vy
Sarin, Simran
Alonso-Caneiro, David
Chakraborty, Ranjay - Abstract:
- Abstract: Research in animal models have shown that exposing the eye to positive or negative spectacle lenses can lead to predictable changes in eye growth. Recent research indicates that brief periods (1–2 h) of monocular defocus results in small, but significant changes in axial length and choroidal thickness of human subjects. However, the effects of the time of day on these ocular changes with defocus are not known. In this study, we examined the effects of monocular myopic and hyperopic defocus on axial length and choroidal thickness when applied in the morning (change between 10 a.m. and 12 p.m.) vs the evening (change between 5 and 7 p.m.) in young adult human participants (mean age, 23.44 ± 4.52 years). A series of axial length (using an IOL Master) and choroidal thickness (using an optical coherence tomographer) measurements were obtained over three consecutive days in both eyes. Day 1 (no defocus) examined the baseline ocular measurements in the morning (10 a.m. and 12 p.m.) and in the evening (5 and 7 p.m.), day 2 investigated the effects of hyperopic and myopic defocus on ocular parameters in the morning (subjects wore a spectacle lens with +3 or −3 DS over the right eye and a plano lens over the left eye between 10 a.m. and 12 p.m.), and day 3 examined the effects of defocus in the evening (+3 or −3 DS spectacle lens over the right eye between 5 and 7 p.m.). Exposure to myopic defocus caused a significant reduction in axial length and thickening of the subfovealAbstract: Research in animal models have shown that exposing the eye to positive or negative spectacle lenses can lead to predictable changes in eye growth. Recent research indicates that brief periods (1–2 h) of monocular defocus results in small, but significant changes in axial length and choroidal thickness of human subjects. However, the effects of the time of day on these ocular changes with defocus are not known. In this study, we examined the effects of monocular myopic and hyperopic defocus on axial length and choroidal thickness when applied in the morning (change between 10 a.m. and 12 p.m.) vs the evening (change between 5 and 7 p.m.) in young adult human participants (mean age, 23.44 ± 4.52 years). A series of axial length (using an IOL Master) and choroidal thickness (using an optical coherence tomographer) measurements were obtained over three consecutive days in both eyes. Day 1 (no defocus) examined the baseline ocular measurements in the morning (10 a.m. and 12 p.m.) and in the evening (5 and 7 p.m.), day 2 investigated the effects of hyperopic and myopic defocus on ocular parameters in the morning (subjects wore a spectacle lens with +3 or −3 DS over the right eye and a plano lens over the left eye between 10 a.m. and 12 p.m.), and day 3 examined the effects of defocus in the evening (+3 or −3 DS spectacle lens over the right eye between 5 and 7 p.m.). Exposure to myopic defocus caused a significant reduction in axial length and thickening of the subfoveal choroid at both times; but, compared to baseline data from day 1, the relative change in axial length (−0.021 ± 0.009 vs +0.004 ± 0.003 mm, p = 0.009) and choroidal thickness (+0.027 ± 0.006 vs +0.007 ± 0.006 mm, p = 0.011) with defocus were significantly greater for evening exposure to defocus than for the morning session. On the contrary, introduction of hyperopic defocus resulted in a significant increase in axial length when given in the morning (+0.026 ± 0.006 mm), but not in the evening (+0.001 ± 0.003 mm) (p = 0.047). Furthermore, hyperopic defocus resulted in a significant thinning of the choroid (p = 0.005), but there was no significant influence of the time of day on choroidal changes associated with hyperopic defocus (p = 0.672). Exposure to hyperopic and myopic defocus at different times of the day was also associated with changes in the parafoveal regions of the choroid (measured across 1.5 mm nasal and temporal choroidal regions on either side of the fovea). Our results show that ocular response to optical defocus varies significantly depending on the time of day in human subjects. These findings represent a potential interaction between the signal associated with the eye's natural diurnal rhythm and the visual signal associated with the optical defocus, making the eye perhaps more responsive to hyperopic defocus (or 'go' signal) in the morning, and to myopic defocus (or 'stop' signal) in the latter half of the day. Highlights: Ocular response to defocus varies depending on the time of day in human subjects. Evening exposure to myopic defocus causes a larger reduction in axial length. Only morning exposure to hyperopic defocus causes an increase in axial length. Axial length changes are associated with opposite changes in choroidal thickness. Ocular diurnal rhythms may influence the eye's response to defocus in humans. … (more)
- Is Part Of:
- Experimental eye research. Volume 182(2019)
- Journal:
- Experimental eye research
- Issue:
- Volume 182(2019)
- Issue Display:
- Volume 182, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 182
- Issue:
- 2019
- Issue Sort Value:
- 2019-0182-2019-0000
- Page Start:
- 125
- Page End:
- 136
- Publication Date:
- 2019-05
- Subjects:
- Hyperopic defocus -- Myopic defocus -- Time of day -- Axial length -- Choroidal thickness -- Myopia
Ophthalmology -- Periodicals
Eye -- Periodicals
Œil -- Périodiques
Ophthalmology
Periodicals
Electronic journals
612.8405 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00144835 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0014-4835;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.exer.2019.03.019 ↗
- Languages:
- English
- ISSNs:
- 0014-4835
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3839.150000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10102.xml