Atomic force microscopy analysis of the effect of plasma treatment on gas permeable contact lens surface topography. Issue 3 (June 2019)
- Record Type:
- Journal Article
- Title:
- Atomic force microscopy analysis of the effect of plasma treatment on gas permeable contact lens surface topography. Issue 3 (June 2019)
- Main Title:
- Atomic force microscopy analysis of the effect of plasma treatment on gas permeable contact lens surface topography
- Authors:
- Gill, Felicity R.
Purslow, Christine
Murphy, Paul J. - Abstract:
- Highlights: Plasma-surface treatment reduces roughness of unworn gas permeable contact lenses. Benefit of plasma treatment continues for at least 3 months of daily wear. No relationship was found between surface roughness and wear comfort. A sample preparation protocol was developed to produce repeatable results. Abstract: Purpose: Using atomic force microscopy (AFM) to investigate anterior surface topography (AST) in worn and unworn, plasma surface-treated (PST) and untreated (UT) gas permeable (GP) lenses, and influence of surface topography on in vivo comfort. Methods: GP lens AST evaluated with AFM in tapping mode, using an uncoated, 40 nm symmetric tip (sampling frequency: 300 kHz), at five randomised locations, over a 100μm 2 area, to produce mean average roughness (Ra) and root mean square (RMS) values for each sample. Four unworn lenses (two PST, two UT) were examined (Quasar/Boston EO material). Twenty worn lenses (ten PST, ten UT) of same design and material as unworn lenses collected after 3 months lens wear. General wearing comfort reported by visual analogue scale (VAS) at 3 months visit. For sample preparation, two worn UT GP lenses were divided into four segments; each segment underwent a different lens rinse and drying method. Results: Unworn: UT lenses had significantly higher mean RMS and Ra values compared to PST (Mann-Whitney, p < 0.05). Worn: UT Median RMS values were significantly higher than PST (Mann-Whitney, p < 0.05). Comfort: no correlation foundHighlights: Plasma-surface treatment reduces roughness of unworn gas permeable contact lenses. Benefit of plasma treatment continues for at least 3 months of daily wear. No relationship was found between surface roughness and wear comfort. A sample preparation protocol was developed to produce repeatable results. Abstract: Purpose: Using atomic force microscopy (AFM) to investigate anterior surface topography (AST) in worn and unworn, plasma surface-treated (PST) and untreated (UT) gas permeable (GP) lenses, and influence of surface topography on in vivo comfort. Methods: GP lens AST evaluated with AFM in tapping mode, using an uncoated, 40 nm symmetric tip (sampling frequency: 300 kHz), at five randomised locations, over a 100μm 2 area, to produce mean average roughness (Ra) and root mean square (RMS) values for each sample. Four unworn lenses (two PST, two UT) were examined (Quasar/Boston EO material). Twenty worn lenses (ten PST, ten UT) of same design and material as unworn lenses collected after 3 months lens wear. General wearing comfort reported by visual analogue scale (VAS) at 3 months visit. For sample preparation, two worn UT GP lenses were divided into four segments; each segment underwent a different lens rinse and drying method. Results: Unworn: UT lenses had significantly higher mean RMS and Ra values compared to PST (Mann-Whitney, p < 0.05). Worn: UT Median RMS values were significantly higher than PST (Mann-Whitney, p < 0.05). Comfort: no correlation found between general comfort and RMS or Ra scores. Sample preparation: Method 4 (purified, distilled water rinse/nitrogen gas dry) produced optimum median RMS and Ra values. Conclusions: Unworn PST GP lenses had lower Ra and RMS values compared with unworn UT GP lenses. After 3 months wear, PST lenses had smoother surface topographies than UT lenses. No relationship was found between surface topography and lens wear comfort. Sample preparation protocol directly impacts AFM results. … (more)
- Is Part Of:
- Contact lens & anterior eye. Volume 42:Issue 3(2019)
- Journal:
- Contact lens & anterior eye
- Issue:
- Volume 42:Issue 3(2019)
- Issue Display:
- Volume 42, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 3
- Issue Sort Value:
- 2019-0042-0003-0000
- Page Start:
- 265
- Page End:
- 272
- Publication Date:
- 2019-06
- Subjects:
- Gas permeable contact lenses -- Plasma-treatment -- Surface roughness -- Comfort
Anterior segment (Eye) -- Periodicals
Contact lenses -- Periodicals
Segment antérieur (Œil) -- Périodiques
Lentilles de contact -- Périodiques
617.752305 - Journal URLs:
- http://firstsearch.oclc.org/journal=1367-0484;screen=info;ECOIP ↗
http://www.sciencedirect.com/science/journal/13670484 ↗
http://www.contactlensjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13670484 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13670484 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clae.2019.02.010 ↗
- Languages:
- English
- ISSNs:
- 1367-0484
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3424.971000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10103.xml