Comparison of methods for converting Dylos particle number concentrations to PM2.5 mass concentrations. (25th March 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of methods for converting Dylos particle number concentrations to PM2.5 mass concentrations. (25th March 2019)
- Main Title:
- Comparison of methods for converting Dylos particle number concentrations to PM2.5 mass concentrations
- Authors:
- Franken, Remy
Maggos, Thomas
Stamatelopoulou, Asimina
Loh, Miranda
Kuijpers, Eelco
Bartzis, John
Steinle, Suzanne
Cherrie, John W.
Pronk, Anjoeka - Abstract:
- Abstract: The aim of this study was to (a) develop a method for converting particle number concentrations (PNC) obtained by Dylos to PM2.5 mass concentrations, (b) compare this conversion with similar methods available in the literature, and (c) compare Dylos PM2.5 obtained using all available conversion methods with gravimetric samples. Data were collected in multiple residences in three European countries using the Dylos and an Aerodynamic Particle Sizer (APS, TSI) in the Netherlands or an optical particle counter (OPC, GRIMM) in Greece. Two statistical fitted curves were developed based on Dylos PNC and either an APS or an OPC particle mass concentrations (PMC). In addition, at the homes of 16 volunteers (UK and Netherlands), Dylos measurements were collected along with gravimetric samples. The Dylos PNC were transformed to PMC using all the fitted curves obtained during this study (and three found in the literature) and were compared with gravimetric samples. The method developed in the present study using an OPC showed the highest correlation (Pearson ( R ) = 0.63, Concordance ( ρ c ) = 0.61) with gravimetric data. The other methods resulted in an underestimation of PMC compared to gravimetric measurements ( R = 0.65‐0.55, ρ c = 0.51‐0.24). In conclusion, estimation of PM2.5 concentrations using the Dylos is acceptable for indicative purposes.
- Is Part Of:
- Indoor air. Volume 29:Number 3(2019)
- Journal:
- Indoor air
- Issue:
- Volume 29:Number 3(2019)
- Issue Display:
- Volume 29, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 29
- Issue:
- 3
- Issue Sort Value:
- 2019-0029-0003-0000
- Page Start:
- 450
- Page End:
- 459
- Publication Date:
- 2019-03-25
- Subjects:
- aerodynamic particle sizer -- conversion -- Dylos -- mass concentration -- optical particle counter -- particle number concentration
Indoor air pollution -- Periodicals
Sick building syndrome -- Periodicals
Ventilation -- Periodicals
613.5 - Journal URLs:
- http://www.blackwell-synergy.com/loi/ina ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0668 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ina.12546 ↗
- Languages:
- English
- ISSNs:
- 0905-6947
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4438.046530
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10091.xml