Application of signal processing techniques for islanding detection of distributed generation in distribution network: A review. (15th May 2015)
- Record Type:
- Journal Article
- Title:
- Application of signal processing techniques for islanding detection of distributed generation in distribution network: A review. (15th May 2015)
- Main Title:
- Application of signal processing techniques for islanding detection of distributed generation in distribution network: A review
- Authors:
- Raza, Safdar
Mokhlis, Hazlie
Arof, Hamzah
Laghari, J.A.
Wang, Li - Abstract:
- Highlights: Pros & cons of conventional islanding detection techniques (IDTs) are discussed. Signal processing techniques (SPTs) ability in detecting islanding is discussed. SPTs ability in improving performance of passive techniques are discussed. Fourier, s-transform, wavelet, HHT & tt-transform based IDTs are reviewed. Intelligent classifiers (ANN, ANFIS, Fuzzy, SVM) application in SPT are discussed. Abstract: High penetration of distributed generation resources (DGR) in distribution network provides many benefits in terms of high power quality, efficiency, and low carbon emissions in power system. However, efficient islanding detection and immediate disconnection of DGR is critical in order to avoid equipment damage, grid protection interference, and personnel safety hazards. Islanding detection techniques are mainly classified into remote, passive, active, and hybrid techniques. From these, passive techniques are more advantageous due to lower power quality degradation, lower cost, and widespread usage by power utilities. However, the main limitations of these techniques are that they possess a large non detection zones and require threshold setting. Various signal processing techniques and intelligent classifiers have been used to overcome the limitations of passive islanding. Signal processing techniques, in particular, are adopted due to their versatility, stability, cost effectiveness, and ease of modification. This paper presents a comprehensive overview of signalHighlights: Pros & cons of conventional islanding detection techniques (IDTs) are discussed. Signal processing techniques (SPTs) ability in detecting islanding is discussed. SPTs ability in improving performance of passive techniques are discussed. Fourier, s-transform, wavelet, HHT & tt-transform based IDTs are reviewed. Intelligent classifiers (ANN, ANFIS, Fuzzy, SVM) application in SPT are discussed. Abstract: High penetration of distributed generation resources (DGR) in distribution network provides many benefits in terms of high power quality, efficiency, and low carbon emissions in power system. However, efficient islanding detection and immediate disconnection of DGR is critical in order to avoid equipment damage, grid protection interference, and personnel safety hazards. Islanding detection techniques are mainly classified into remote, passive, active, and hybrid techniques. From these, passive techniques are more advantageous due to lower power quality degradation, lower cost, and widespread usage by power utilities. However, the main limitations of these techniques are that they possess a large non detection zones and require threshold setting. Various signal processing techniques and intelligent classifiers have been used to overcome the limitations of passive islanding. Signal processing techniques, in particular, are adopted due to their versatility, stability, cost effectiveness, and ease of modification. This paper presents a comprehensive overview of signal processing techniques used to improve common passive islanding detection techniques. A performance comparison between the signal processing based islanding detection techniques with existing techniques are also provided. Finally, this paper outlines the relative advantages and limitations of the signal processing techniques in order to provide basic guidelines for researchers and field engineers in determining the best method for their system. … (more)
- Is Part Of:
- Energy conversion and management. Volume 96(2015)
- Journal:
- Energy conversion and management
- Issue:
- Volume 96(2015)
- Issue Display:
- Volume 96, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 96
- Issue:
- 2015
- Issue Sort Value:
- 2015-0096-2015-0000
- Page Start:
- 613
- Page End:
- 624
- Publication Date:
- 2015-05-15
- Subjects:
- Islanding detection -- Signal processing -- Fourier transform -- Wavelet transform -- s-transform -- Hilbert Huang transform -- tt-transform
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2015.03.029 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10091.xml