Retrospective analysis for valproate screening targets with liquid chromatography–high resolution mass spectrometry with positive electrospray ionization: An omics‐based approach. Issue 5 (13th December 2018)
- Record Type:
- Journal Article
- Title:
- Retrospective analysis for valproate screening targets with liquid chromatography–high resolution mass spectrometry with positive electrospray ionization: An omics‐based approach. Issue 5 (13th December 2018)
- Main Title:
- Retrospective analysis for valproate screening targets with liquid chromatography–high resolution mass spectrometry with positive electrospray ionization: An omics‐based approach
- Authors:
- Mollerup, Christian Brinch
Rasmussen, Brian Schou
Johansen, Sys Stybe
Mardal, Marie
Linnet, Kristian
Dalsgaard, Petur Weihe - Abstract:
- Abstract: Liquid chromatography coupled with high‐resolution mass spectrometry (LC–HRMS) is an important analytical tool in the systematic toxicological analysis performed in forensic toxicology. However, some important compounds, such as the antiepileptic drug valproate (valproic acid; VPA), cannot be directly detected with positive electrospray ionization (ESI + ) due to poor ionization. Here we demonstrate an omics‐based retrospective analysis for the identification of indirect screening targets for VPA in whole blood with LC–ESI + –HRMS. Analysis was performed utilizing data acquired across four years from LC–ESI + –HRMS, with VPA results from a quantitative LC–MS/MS method. The combined data with VPA results were split into an exploration set ( n = 68; 28% positive) and a test set ( n = 37; 32% positive). Eight indirect targets for VPA were identified in the exploration set. The evaluation of these targets was confirmed with retrospective target analysis of the test set. Using a combination of two out of the eight indirect targets, we attained a sensitivity of 92% ( n = 12; VPA concentration range: 4.4–29.7 mg/kg) and 100% specificity ( n = 25) for VPA with LC–ESI + –HRMS. VPA screening targets were identified with retrospective data analysis and could be appended to the existing screening procedure. A sensitive and specific screening with LC–ESI + –HRMS was achieved with targets corresponding to the sodium adducts of C7 H14 O3 and C8 H14 O3 . Three chromatographicAbstract: Liquid chromatography coupled with high‐resolution mass spectrometry (LC–HRMS) is an important analytical tool in the systematic toxicological analysis performed in forensic toxicology. However, some important compounds, such as the antiepileptic drug valproate (valproic acid; VPA), cannot be directly detected with positive electrospray ionization (ESI + ) due to poor ionization. Here we demonstrate an omics‐based retrospective analysis for the identification of indirect screening targets for VPA in whole blood with LC–ESI + –HRMS. Analysis was performed utilizing data acquired across four years from LC–ESI + –HRMS, with VPA results from a quantitative LC–MS/MS method. The combined data with VPA results were split into an exploration set ( n = 68; 28% positive) and a test set ( n = 37; 32% positive). Eight indirect targets for VPA were identified in the exploration set. The evaluation of these targets was confirmed with retrospective target analysis of the test set. Using a combination of two out of the eight indirect targets, we attained a sensitivity of 92% ( n = 12; VPA concentration range: 4.4–29.7 mg/kg) and 100% specificity ( n = 25) for VPA with LC–ESI + –HRMS. VPA screening targets were identified with retrospective data analysis and could be appended to the existing screening procedure. A sensitive and specific screening with LC–ESI + –HRMS was achieved with targets corresponding to the sodium adducts of C7 H14 O3 and C8 H14 O3 . Three chromatographic resolved isomer peaks were observed for the latter, and the consistently most intense peak was tentatively identified as 3‐hydroxy‐4‐en‐VPA. Abstract : Important compounds, such as valproate, cannot be directly detected using positive electrospray ionization LC‐MS. However, retrospective analysis of positive electrospray ionization LC‐HRMS screening data, identified indirect targets for valproate in an exploration set (n = 68, 28% positive). Target analysis using these indirect targets identified valproate with 97% accuracy in a test set ( n = 37, 32% positive). … (more)
- Is Part Of:
- Drug testing and analysis. Volume 11:Issue 5(2019)
- Journal:
- Drug testing and analysis
- Issue:
- Volume 11:Issue 5(2019)
- Issue Display:
- Volume 11, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 5
- Issue Sort Value:
- 2019-0011-0005-0000
- Page Start:
- 730
- Page End:
- 738
- Publication Date:
- 2018-12-13
- Subjects:
- biomarker -- forensic toxicology screening -- indirect screening -- retrospective analysis -- untargeted high‐resolution mass spectrometry screening
Drugs -- Analysis -- Periodicals
Drug testing -- Periodicals
Chemistry, Forensic -- Periodicals
615.1901 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1942-7611 ↗
http://rzblx1.uni-regensburg.de/ezeit/warpto.phtml?colors=7&jour_id=110501 ↗
http://www3.interscience.wiley.com/journal/121408477/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/dta.2543 ↗
- Languages:
- English
- ISSNs:
- 1942-7603
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3629.424000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10079.xml